EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Vibration-stimulation device–assisted enhanced recovery after lower limb fracture surgery: A randomized controlled trial

Tai-Long Shi, Zhen-Bang Yang, Yu-Qin Zhang, Zi-Xi Fan, Kai Ding, Si-Ming Jia, Juan Wang, Lu-Qing Di, Wei Chen

International Orthopaedics · 2026

DOI: 10.1007/s00264-025-06726-7 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift International Orthopaedics, 2026. Verfasst von Tai-Long Shi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China. Hauptthemen laut MEDLINE: Vibration, Enhanced Recovery After Surgery, Fractures, Bone, Lower Extremity. Die Arbeit nennt 35 Literaturangaben. Gefördert von: the Key Projects of the National Natural Science Foundation of China, Natural Science Foundation of Hebei Province (CN) - for Yanzhao Young Scientists Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: In the context of the widespread implementation of enhanced recovery after surgery (ERAS) in orthopaedics, postoperative supportive interventions for patients with lower limb fractures remain limited. This study aimed to introduce a vibration-stimulation device designed in accordance with ERAS principles and to evaluate its clinical effectiveness. METHODS: This prospective randomized controlled trial consecutively screened 1,241 patients aged 18-75 years with lower limb fractures admitted to a tertiary university-affiliated orthopaedic hospital between January and December 2024, of whom 707 met the inclusion criteria. Patients were randomly assigned in a 1:1 ratio by a random number table to a vibration group or a blank control group. The primary outcomes were the seven day postoperative pain visual analogue scale (VAS) score and the incidence of lower limb deep vein thrombosis (DVT). Secondary outcomes were radiographic fracture-healing time and postoperative functional scores. The primary analysis followed the intention-to-treat (ITT) principle, comparing all randomized patients with available outcome data according to their original allocation, and a per-protocol (PP) sensitivity analysis was additionally performed. RESULTS: A total of 707 patients completed six to 12 months of follow-up and were included in the ITT analysis (350 in the vibration group and 357 in the control group). In the overall population, the seven day postoperative incidence of lower limb DVT was significantly lower in the vibration group than in the control group [10.9% (38/350) vs 22.6% (81/357); absolute risk difference (ARD) = 11.7%]. The seven day postoperative pain scores were lower in the vibration group (weighted mean approximately 5.1 vs 5.7), radiographic fracture-healing time was shorter (approximately 5.2 vs 5.5 months), and functional scores at final follow-up were higher (approximately 127.8 vs 123.2). PP sensitivity analyses yielded results consistent in direction with the ITT analyses, further supporting the robustness of the study conclusions. CONCLUSION: Vibration-stimulation therapy facilitates rapid postoperative recovery in patients with lower limb fractures and has a favourable safety profile, and may represent a promising component of postoperative ERAS strategies in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VibrationEnhanced Recovery After SurgeryFractures, BoneLower ExtremityHumansMiddle AgedMaleFemaleAdultAgedProspective StudiesYoung AdultPostoperative PainAdolescentPain MeasurementVenous ThrombosisFracture Healing

Stichwörter der Autor:innen

Enhanced recovery after surgeryFracture healingLower limb fractureVibration-stimulation device

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China.
  • Engineering Research Center of Orthopedic MinimallyInvasive Intelligent Equipment, China Ministry of Education, Shijiazhuang, Hebei Province, China.
  • Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, China.
  • NHC Key Laboratory of Intelligent Orthopaedic Equipment, Shijiazhuang, Hebei, China.
  • Key Laboratory of Precise Assessment, Diagnosis, and Treament of Soft Tissue Injury of Hebei Province, Hebei, China.
  • Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China. dlq7415918@sina.com.

Förderung

  • the Key Projects of the National Natural Science Foundation of China
  • Natural Science Foundation of Hebei Province (CN) - for Yanzhao Young Scientists Project

Zitieren

APA

Shi, T. L., Yang, Z. B., Zhang, Y. Q., Fan, Z. X., Ding, K., Jia, S. M., Wang, J., Di, L. Q., & Chen, W. (2026). Vibration-stimulation device–assisted enhanced recovery after lower limb fracture surgery: A randomized controlled trial. International Orthopaedics. https://doi.org/10.1007/s00264-025-06726-7

Vancouver

Shi TL, Yang ZB, Zhang YQ, Fan ZX, Ding K, Jia SM, et al. Vibration-stimulation device–assisted enhanced recovery after lower limb fracture surgery: A randomized controlled trial. International Orthopaedics. 2026. doi:10.1007/s00264-025-06726-7

BibTeX
@article{Shi2026,
  author = {Shi, Tai-Long and Yang, Zhen-Bang and Zhang, Yu-Qin and Fan, Zi-Xi and Ding, Kai and Jia, Si-Ming and Wang, Juan and Di, Lu-Qing and Chen, Wei},
  title = {Vibration-stimulation device–assisted enhanced recovery after lower limb fracture surgery: A randomized controlled trial},
  journal = {International Orthopaedics},
  year = {2026},
  doi = {10.1007/s00264-025-06726-7}
}
Kostenlos starten →