EUVIMEDEUVIMED entdecken
Crossref

Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode

Yasuaki Tamaki, Keizo Wada, Shota Shigekiyo, Yuto Sugimine, Ken Tomonari, Koichi Sairyo

International Orthopaedics · 2026

DOI: 10.1007/s00264-025-06723-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Orthopaedics, 2026. Verfasst von Yasuaki Tamaki und 5 weiteren Autor:innen. Beteiligte Einrichtung: 3-18-15 Kuramoto, Tokushima University, Tokushima, Japan. footballtravel0309@yahoo.co.jp. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Leg Length Inequality, Femur. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study evaluated the accuracy of intraoperative leg length and femoral anteversion measurements obtained during total hip arthroplasty (THA) using the Mako robotic system with enhanced mode. METHODS: A total of 55 hips in four men and 51 women who underwent primary THA with the Mako system via an anterolateral approach were retrospectively evaluated. Intraoperative measurements of leg length and femoral anteversion displayed by the Mako enhanced mode were compared with postoperative CT-based measurements. Absolute errors and their distributions were calculated to assess the accuracy of intraoperative assessments. RESULTS: The mean absolute error was 2.3 ± 1.8 mm for postoperative leg length discrepancy and 2.9 ± 2.2° for stem anteversion. Of the 55 hips, 46 (83.6%) showed leg length errors within 3 mm and 51 (92.7%) within 5 mm. For stem anteversion, 48 hips (87.3%) were within 3° and all 55 hips (100%) were within 5°. Mako enhanced mode could not be completed in 10.7% of cases because of femoral array loosening or screw penetration into the medullary canal. CONCLUSION: Mako enhanced mode demonstrated clinically acceptable accuracy for intraoperative measurement of leg length and femoral anteversion, contributing to precise femoral stem implantation in robotic-assisted THA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipRobotic Surgical ProceduresLeg Length InequalityFemurHumansFemaleMaleMiddle AgedRetrospective StudiesAgedHip ProsthesisAdultTomography, X-Ray ComputedHip JointIntraoperative Period

Stichwörter der Autor:innen

Enhanced modeHipMakoRoboticsTotal hip arthroplasty

Autor:innen und Institutionen

  • 3-18-15 Kuramoto, Tokushima University, Tokushima, Japan. footballtravel0309@yahoo.co.jp.
  • 3-18-15 Kuramoto, Tokushima University, Tokushima, Japan.

Zitieren

APA

Tamaki, Y., Wada, K., Shigekiyo, S., Sugimine, Y., Tomonari, K., & Sairyo, K. (2026). Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode. International Orthopaedics. https://doi.org/10.1007/s00264-025-06723-w

Vancouver

Tamaki Y, Wada K, Shigekiyo S, Sugimine Y, Tomonari K, Sairyo K. Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode. International Orthopaedics. 2026. doi:10.1007/s00264-025-06723-w

BibTeX
@article{Tamaki2026,
  author = {Tamaki, Yasuaki and Wada, Keizo and Shigekiyo, Shota and Sugimine, Yuto and Tomonari, Ken and Sairyo, Koichi},
  title = {Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode},
  journal = {International Orthopaedics},
  year = {2026},
  doi = {10.1007/s00264-025-06723-w}
}
Kostenlos starten →