EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up

Philipp Schippers iD, Felix Wunderlich, Yama Afghanyar, Victoria Buschmann, Thomas Klonschinski, Philipp Drees, Lukas Eckhard

International Orthopaedics · 2024

DOI: 10.1007/s00264-024-06325-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Orthopaedics, 2024. Verfasst von Philipp Schippers und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany. philipp.schippers@u…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Patient Satisfaction, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsmedizin der Johannes Gutenberg-Universität Mainz.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Despite numerous studies demonstrating promising short-term outcomes of Total Knee Arthroplasty (TKA) with Customized Individually Made (CIM) implants, there is a significant lack of data on their mid-term effectiveness. Given the increasing number of TKAs performed annually, the rising demand for CIM implants, and the associated burden of revision surgeries, understanding the mid-term performance of CIM implants is crucial. Therefore, this study aims to report on the mid-term (minimum 5 years) outcomes of TKA using a CIM implant.

Methods

This retrospective cohort study included a consecutive series of 116 patients who received the ConforMIS ® iTotal CR implant between 2015 and 2018. Inclusion criteria were end-stage knee osteoarthritis with coronal deformities below 10° and absence of ligamentous instability. Exclusion criteria included simultaneous bilateral TKA. Patients were followed up at a minimum of five years post-surgery. They completed a questionnaire reporting on satisfaction, pain levels using the Visual Analogue Scale (VAS), current weight, the Oxford Knee Score (OKS), and the Forgotten Joint Score for the knee (FJS-knee). Statistical analysis included descriptive statistics for demographic and clinical variables, and outcomes were reported as means with ranges.

Results

The mean follow-up duration was 5.9 ± 0.8 years (range 5–7.4 years). 90% of patients stated they would undergo the same operation again, and 93% were either satisfied or very satisfied. The mean VAS for pain at rest was 2 ± 1.5 (range 0–6) and during exercise was 3 ± 2 (range 0–8). 58 patients (53%) managed to lose weight. The mean OKS was 41 ± 9 points (range 15–48), and the mean FJS-knee was 67 ± 23 points (range 4–100). No severe complications occurred.

Conclusion

CIM TKA using the ConforMIS ® iTotal CR implant can achieve excellent results with 93% of patients being satisfied or very satisfied at mid-term follow-up of five years. Prospective, randomized, and patient-blinded trials comparing off-the-shelf (OTS) TKAs with CIM implants are necessary to evaluate whether these implants are superior or not.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneePatient SatisfactionKnee ProsthesisOsteoarthritis, KneeHumansFemaleMaleRetrospective StudiesAgedMiddle AgedFollow-Up StudiesProsthesis DesignTreatment OutcomeSurveys and QuestionnairesKnee JointAged, 80 and overPain Measurement

Stichwörter der Autor:innen

ConformisCustomized, individually madeTotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany. philipp.schippers@unimedizin-mainz.de.
  • Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
  • Praxis für Gelenkchirurgie Bad Kreuznach, 55543, Bad Kreuznach, Germany.

ORCID-Profile: Philipp Schippers

Förderung

  • Universitätsmedizin der Johannes Gutenberg-Universität Mainz

Zitieren

APA

Schippers, P., Wunderlich, F., Afghanyar, Y., Buschmann, V., Klonschinski, T., Drees, P., & Eckhard, L. (2024). High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up. International Orthopaedics. https://doi.org/10.1007/s00264-024-06325-y

Vancouver

Schippers P, Wunderlich F, Afghanyar Y, Buschmann V, Klonschinski T, Drees P, et al. High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up. International Orthopaedics. 2024. doi:10.1007/s00264-024-06325-y

BibTeX
@article{Schippers2024,
  author = {Schippers, Philipp and Wunderlich, Felix and Afghanyar, Yama and Buschmann, Victoria and Klonschinski, Thomas and Drees, Philipp and Eckhard, Lukas},
  title = {High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up},
  journal = {International Orthopaedics},
  year = {2024},
  doi = {10.1007/s00264-024-06325-y}
}
Kostenlos starten →