Implementation of a biparametric prostate MRI protocol with a recall system for intravenous contrast: an analysis of recall rates and comparison of PI-RADS category distribution
Abdominal Radiology · 2025
DOI: 10.1007/s00261-025-05223-0 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Abdominal Radiology, 2025. Verfasst von John-David Brown und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada. jdbrown@dal.ca. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Contrast Media, Magnetic Resonance Imaging, Multiparametric Magnetic Resonance Imaging. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: The prostate magnetic resonance imaging (MRI) protocol changed from a contrast multiparametric MRI (mp-MRI) to a non-contrast biparametric (bp-MRI) protocol at a single centre. This study describes the recall rate, median time to recall, and PI-RADS distribution pre-/post-implementation. METHODS: This retrospective descriptive study involved a consecutive sample of all 3 Tesla (3T) prostate bp-MRIs following the protocol change (01April2023-23May2024) to determine the proportion of bp-MRIs recalled, the indications for recall, and the median time until recall MRI (Part 1). A subset of these prostate MRIs was compared to a consecutive sample immediately prior to the change in protocol to compare the distribution of PI-RADS categories (Part 2). The distribution of MRI reporting frequency by radiologists was compared pre-/post-implementation (Part 2). INCLUSION CRITERIA: 3T bp-MRI protocol, out-patient, male, and ≥ 18 years of age. RESULTS: A total of 554 prostate bp-MRIs took place during the study period, 547 (96.8%) were included. Of the 547 subjects, 36 (6.6%) were recalled for intravenous (IV) contrast. Most recalls were for PI-RADS 3 reassessment (33/36, 91.7%). PI-RADS categories were upgraded from 3 to 4 in 16/33 (48.5%) subjects. The median time between initial and recall MRI was 35 days. There was no statistically significant difference in the distribution of PI-RADS categories before (n = 225) and after (n = 225) implementation of the bp-MRI protocol (X2, p = 0.09). There was no statistically significant difference in the distribution of MRI reporting frequency by radiologists pre-/post-implementation (X2, p = 0.06). CONCLUSION: A small proportion (6.6%) of bp-MRI subjects were recalled for contrast reassessment and the majority of those (91.7%) were for PI-RADS 3 reassessment. There was no statistically significant difference in the distribution of PI-RADS categories following implementation of the bp-MRI protocol. Implementation of a bp-MRI protocol at a single centre reduced patient exposure to IV contrast while not changing PI-RADS distribution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada. jdbrown@dal.ca.
- Faculty of Medicine, Dalhousie University, Halifax, Canada. jdbrown@dal.ca.
- Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada.
- Faculty of Medicine, Dalhousie University, Halifax, Canada.
Zitieren
APA
Brown, J. D., Payne, J., & Clarke, S. E. (2025). Implementation of a biparametric prostate MRI protocol with a recall system for intravenous contrast: an analysis of recall rates and comparison of PI-RADS category distribution. Abdominal Radiology. https://doi.org/10.1007/s00261-025-05223-0
Vancouver
Brown JD, Payne J, Clarke SE. Implementation of a biparametric prostate MRI protocol with a recall system for intravenous contrast: an analysis of recall rates and comparison of PI-RADS category distribution. Abdominal Radiology. 2025. doi:10.1007/s00261-025-05223-0
BibTeX
@article{Brown2025,
author = {Brown, John-David and Payne, Jennifer and Clarke, Sharon E},
title = {Implementation of a biparametric prostate MRI protocol with a recall system for intravenous contrast: an analysis of recall rates and comparison of PI-RADS category distribution},
journal = {Abdominal Radiology},
year = {2025},
doi = {10.1007/s00261-025-05223-0}
}
EUVIMED