EUVIMEDEUVIMED entdecken
Crossref

Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation

Thitinan Chulroek, Ratchaya Ariyasaksakul

Abdominal Radiology · 2026

DOI: 10.1007/s00261-026-05484-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2026. Verfasst von Thitinan Chulroek und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Magnetic Resonance Imaging. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate whether measurement of prostate lesion size on sagittal or coronal imaging planes influences PI-RADS v2.1 categorization and histopathologic correlation compared with axial measurement. METHODS: In this single-center retrospective study, 261 prostate lesions categorized as PI-RADS 4 or 5 underwent subsequent targeted MRI/TRUS fusion biopsy or prostatectomy. Lesion size was measured as maximal axial diameter (MAD) and maximal coronal or sagittal diameter (MCSD). Lesions were subsequently categorized according to PI-RADS v2.1 using these measurements. The agreement between MAD and MCSD was assessed using a Bland-Altman analysis. Measurement reliability and interobserver agreement were evaluated using intraclass correlation coefficients (ICC). Kappa statistics were used to assess agreement in PI-RADS categorization for clinically significant prostate cancer. RESULT: Bland-Altman analysis demonstrated minimal bias and strong agreement between MAD and MCSD measurements for the whole prostate (mean difference 0.28 mm; 95% limits of agreement - 2.62 to 3.19 mm), with similar results in both the peripheral and transition zones. Intraclass correlation analysis showed excellent reliability between measurements (ICC = 0.93). Agreement in PI-RADS categorization between MAD and MCSD was almost perfect (κ = 0.931). Reclassification from PI-RADS 4 to 5 occurred in 1.74% of lesions when using MCSD, and all reclassified lesions demonstrated clinically significant prostate cancer on histopathology. CONCLUSION: MAD and MCSD measurements of prostate lesion size demonstrate excellent agreement and highly concordant PI-RADS categorization. Although reclassification is uncommon, evaluation of the sagittal or coronal planes may provide additional value for selected lesions with craniocaudal elongation, where the maximal tumor extent may not be fully represented on axial images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsMagnetic Resonance ImagingHumansMaleRetrospective StudiesReproducibility of ResultsMiddle AgedAgedRadiology Information SystemsProstateProstatectomyContrast MediaImage-Guided Biopsy

Stichwörter der Autor:innen

Imaging, disease, method, classification systemLesion size measurementMeasurement agreementMultiparametric magnetic resonance imaging (mpMRI)Multiplanar imagingPI-RADS v2.1Prostate MRIProstate cancerProstatic neoplasms

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Department of Diagnostic Radiology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Ratchaya.A@chula.ac.th.

Zitieren

APA

Chulroek, T., & Ariyasaksakul, R. (2026). Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation. Abdominal Radiology. https://doi.org/10.1007/s00261-026-05484-3

Vancouver

Chulroek T, Ariyasaksakul R. Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation. Abdominal Radiology. 2026. doi:10.1007/s00261-026-05484-3

BibTeX
@article{Chulroek2026,
  author = {Chulroek, Thitinan and Ariyasaksakul, Ratchaya},
  title = {Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation},
  journal = {Abdominal Radiology},
  year = {2026},
  doi = {10.1007/s00261-026-05484-3}
}
Kostenlos starten →