Diagnostic value of combining ultrafast cine MRI and morphological measurements on gastroesophageal reflux disease
Abdominal Radiology · 2025
DOI: 10.1007/s00261-025-04890-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Qing Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Beichen Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Gastroesophageal Reflux, Magnetic Resonance Imaging, Cine. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Tianjin Beichen Science and Technology Grant.
Abstract (Originalsprache)
PURPOSE: To evaluate the diagnostic performance of combining ultrafast real-time cine MRI with morphological measurements on gastroesophageal reflux disease (GERD). METHODS: In the prospective study, 40 healthy volunteers and 30 GERD patients underwent real-time cine MRI using an undersampled low-angle gradient echo sequence (50 ms/frame) with deep-learning reconstruction, to monitor the gastroesophageal junction (GEJ) and observe the reflux of the contrast agent during the Valsalva maneuver. The width of the lower esophagus, the length of the lower esophageal sphincter (LES), the end-expiratory and post Valsalva maneuver His angle were measured. RESULTS: There were no statistical differences between the two group either in lower esophageal width (14.06 ± 1.50 mm vs. 14.75 ± 1.57 mm, P > 0.05) or LES length (25.20 ± 1.46 mm vs. 24.39 ± 1.68 mm, P > 0.05). The end-expiratory His angle (84.45 ± 18.67°) and post Valsalva maneuver His angle (101.53 ± 19.22°), and the differences between them (17.08 ± 5.65°) in the GERD group were greater than those in the healthy volunteers (71.51 ± 18.01°, 86.09 ± 18.24°, 14.57 ± 3.88° respectively, P < 0.05). Reflux was induced in 8 cases of GERD group including 4 cases with hiatus hernia and not observed in healthy volunteers. The AUC for diagnosing GERD were 0.702, 0.737 and 0.634 for end-expiratory, post Valsalva maneuver His angle and their differences, when combined with real-time MRI was 0.823, with a sensitivity of 86.67% and a specificity of 67.50%. CONCLUSION: Real-time MRI can display dynamic swallowing and reflux at the GEJ. The His angle can serve as a morphological indicator for diagnosing GERD with MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tianjin Beichen Hospital, Tianjin, China.
- Tianjin Medical University General Hospital, Tianjin, China.
- Tianjin Medical University General Hospital, Tianjin, China. sunhaoran2006@hotmail.com.
Förderung
- Tianjin Beichen Science and Technology Grant
Zitieren
APA
Liu, Q., Xin, Y., Wu, C., Li, J., Song, H., Zhang, Y., Fu, J., Jia, Z., & Sun, H. (2025). Diagnostic value of combining ultrafast cine MRI and morphological measurements on gastroesophageal reflux disease. Abdominal Radiology. https://doi.org/10.1007/s00261-025-04890-3
Vancouver
Liu Q, Xin Y, Wu C, Li J, Song H, Zhang Y, et al. Diagnostic value of combining ultrafast cine MRI and morphological measurements on gastroesophageal reflux disease. Abdominal Radiology. 2025. doi:10.1007/s00261-025-04890-3
BibTeX
@article{Liu2025,
author = {Liu, Qing and Xin, Yujing and Wu, Chao and Li, Jing and Song, Hongyan and Zhang, Yihong and Fu, Jie and Jia, Zhi and Sun, Haoran},
title = {Diagnostic value of combining ultrafast cine MRI and morphological measurements on gastroesophageal reflux disease},
journal = {Abdominal Radiology},
year = {2025},
doi = {10.1007/s00261-025-04890-3}
}
EUVIMED