Comparing two deep learning spectral reconstruction levels for abdominal evaluation using a rapid-kVp-switching dual-energy CT scanner
Abdominal Radiology · 2025
DOI: 10.1007/s00261-025-04868-1 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Hakki Serdar Sagdic und 11 weiteren Autor:innen. Beteiligte Einrichtung: Radiomics and Augmented Intelligence Laboratory (RAIL), Department of Radiology and the Norman Fixel Institute for Neurological Diseases, University …. Hauptthemen laut MEDLINE: Deep Learning, Tomography, X-Ray Computed, Radiography, Abdominal, Radiography, Dual-Energy Scanned Projection. Die Arbeit nennt 53 Literaturangaben. Gefördert von: Canon Medical Systems USA.
Abstract (Originalsprache)
PURPOSE: Deep Learning Spectral Reconstruction (DLSR) potentially improves dual-energy CT (DECT) image quality, but there is a paucity of research involving human abdominal DECT scans. The purpose of this study was to comprehensively evaluate image quality by quantitatively and qualitatively comparing strong and standard levels of a DLSR algorithm. Optimal virtual monochromatic image (VMI) energy levels were also evaluated. METHODS: DECT scans of the abdomen/pelvis from 51 patients were retrospectively evaluated. VMIs were reconstructed at energy levels ranging from 35 to 200 keV using both standard and strong DLSR levels. For quantitative analysis, various abdominal structures were assessed using regions of interest, and mean signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values were calculated. This was supplemented with a qualitative evaluation of VMIs reconstructed at 35, 45, 55, and 65 keV. RESULTS: The strong-level DLSR demonstrated significantly better SNR and CNR values (p < 0.0001) compared to standard-level DLSR across all structures. The optimal SNR was observed at 70 keV (p < 0.0001), while the optimal CNR was found at 65 keV (p < 0.0001). The average qualitative scores between standard and strong DLSR were significantly different at 45, 55, and 65 keV (p < 0.0001). There was a moderate level of agreement between observers (ICC = 0.427, p < 0.0001). CONCLUSION: A DLSR set to a strong level significantly improves image quality compared to standard-level DLSR, potentially enhancing the diagnostic evaluation of abdominal DECT scans. In addition to achieving a very high SNR, 65 keV VMIs had the highest CNR, which differs from what is typically observed with traditional DECT using non-deep learning reconstruction approaches.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiomics and Augmented Intelligence Laboratory (RAIL), Department of Radiology and the Norman Fixel Institute for Neurological Diseases, University of Florida College of Medicine, Gainesville, FL, USA. drsagdic@gmail.c…
- Department of Radiology, University of Florida College of Medicine, Gainesville, FL, USA. drsagdic@gmail.com.
- Radiomics and Augmented Intelligence Laboratory (RAIL), Department of Radiology and the Norman Fixel Institute for Neurological Diseases, University of Florida College of Medicine, Gainesville, FL, USA.
- Department of Radiology, University of Florida College of Medicine, Gainesville, FL, USA.
- Department of Neurosurgery, University of Florida College of Medicine, Gainesville, USA.
- Radiomics and Augmented Intelligence Laboratory (RAIL), Department of Radiology and the Norman Fixel Institute for Neurological Diseases, University of Florida College of Medicine, Gainesville, FL, USA. reza.forghani.md…
Förderung
- Canon Medical Systems USA
Zitieren
APA
Sagdic, H. S., Hosseini-Siyanaki, M., Raviprasad, A., Munjerin, S., Fabri, D., Grajo, J., Tonso, V. M., Magnelli, L., Hochhegger, D., Anthony, E., Hochhegger, B., & Forghani, R. (2025). Comparing two deep learning spectral reconstruction levels for abdominal evaluation using a rapid-kVp-switching dual-energy CT scanner. Abdominal Radiology. https://doi.org/10.1007/s00261-025-04868-1
Vancouver
Sagdic HS, Hosseini-Siyanaki M, Raviprasad A, Munjerin S, Fabri D, Grajo J, et al. Comparing two deep learning spectral reconstruction levels for abdominal evaluation using a rapid-kVp-switching dual-energy CT scanner. Abdominal Radiology. 2025. doi:10.1007/s00261-025-04868-1
BibTeX
@article{Sagdic2025,
author = {Sagdic, Hakki Serdar and Hosseini-Siyanaki, Mohammadreza and Raviprasad, Abheek and Munjerin, Sefat and Fabri, Daniella and Grajo, Joseph and Tonso, Victor Martins and Magnelli, Laura and Hochhegger, Daniela and Anthony, Evelyn and Hochhegger, Bruno and Forghani, Reza},
title = {Comparing two deep learning spectral reconstruction levels for abdominal evaluation using a rapid-kVp-switching dual-energy CT scanner},
journal = {Abdominal Radiology},
year = {2025},
doi = {10.1007/s00261-025-04868-1}
}
EUVIMED