EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Establishing normal myocardial blood flow and myocardial flow reserve values: a rubidium-82 positron emission tomography study

Martin Lyngby Lassen iD, Niels Høeg Brandt-Jacobsen, Piotr Slomka, Tine W Hansen, Yeliz Bulut, Caroline Kistorp, Andreas Kjaer, Philip Hasbak

European Journal of Nuclear Medicine and Molecular Imaging · 2026-08 · 53 (10) · 6075-6084

DOI: 10.1007/s00259-026-07983-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 06.06.2026. Verfasst von Martin Lyngby Lassen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark. martin.lyngby.lassen@regionh.dk. Hauptthemen laut MEDLINE: Rubidium Radioisotopes, Positron-Emission Tomography, Coronary Circulation. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Copenhagen University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Quantitative Rubidium-82 ( 82 Rb) PET allows assessment of myocardial blood flow (MBF) and flow reserve (MFR), yet clinically applicable normal reference ranges remain incompletely defined across age and sex. This study aims to establish age- and sex-specific reference ranges for resting MBF (rMBF), stress MBF (sMBF), and MFR using 82 Rb PET in healthy adults.

Methods

Data from four cohorts of 277 carefully screened healthy adults (143 women, 134 men) aged 19–79 years were examined with an identical 82 Rb PET protocol on the same scanner. Global rMBF, sMBF, and MFR were quantified with a 1-tissue compartment model. Age- and sex-specific percentiles were derived using natural spline regressions.

Results

Median [IQR] rMBF was 1.00 [0.82; 1.18] mL/g/min, sMBF was 3.25 [2.82; 3.58] mL/g/min, and MFR was 3.18 [2.77; 3.86]. The rMBF increased with age (~ 1% per year), while sMBF and MFR decreased with age (sMBF ~-0.1%, MFR ~ -0.6% per year). Women had higher rMBF and sMBF, but lower MFR than men. Age- and sex-specific percentile curves (5–95%) demonstrated substantial physiologic variation in rMBF, sMBF, and MFR across the adult lifespan.

Conclusion

This study establishes reference percentiles for rMBF, sMBF, and MFR derived from a uniform multicohort dataset of healthy adults, aged 19–79 years. These values may aid clinical interpretation of quantitative perfusion PET. These reference percentiles are intended to complement – rather than replace – validated prognostic thresholds for sMBF and MFR. As the population was almost exclusively Euro-Caucasian with body mass index in the normal to moderately overweight range, validation in more diverse cohorts is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rubidium RadioisotopesPositron-Emission TomographyCoronary CirculationHumansFemaleMaleAdultMiddle AgedReference ValuesAgedYoung Adult

Stichwörter der Autor:innen

MBFMFRNormal materialRubidium-82

Substanzen

Rubidium RadioisotopesRubidium-82

Autor:innen und Institutionen

  • Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark. martin.lyngby.lassen@regionh.dk.
  • Cluster for Molecular Imaging, Department of Biomedical Sciences, Copenhagen University, Copenhagen, Denmark. martin.lyngby.lassen@regionh.dk.
  • Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark.
  • Division of Artificial Intelligence, Department of Medicine, Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Steno Diabetes Center Copenhagen, Copenhagen, Denmark.
  • Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

ORCID-Profile: Martin Lyngby Lassen

Förderung

  • Copenhagen University

Zitieren

APA

Lassen, M. L., Brandt-Jacobsen, N. H., Slomka, P., Hansen, T. W., Bulut, Y., Kistorp, C., Kjaer, A., & Hasbak, P. (2026). Establishing normal myocardial blood flow and myocardial flow reserve values: a rubidium-82 positron emission tomography study. European Journal of Nuclear Medicine and Molecular Imaging, 53(10), 6075-6084. https://doi.org/10.1007/s00259-026-07983-3

Vancouver

Lassen ML, Brandt-Jacobsen NH, Slomka P, Hansen TW, Bulut Y, Kistorp C, et al. Establishing normal myocardial blood flow and myocardial flow reserve values: a rubidium-82 positron emission tomography study. European Journal of Nuclear Medicine and Molecular Imaging. 2026;53(10):6075-6084. doi:10.1007/s00259-026-07983-3

BibTeX
@article{Lassen2026,
  author = {Lassen, Martin Lyngby and Brandt-Jacobsen, Niels Høeg and Slomka, Piotr and Hansen, Tine W and Bulut, Yeliz and Kistorp, Caroline and Kjaer, Andreas and Hasbak, Philip},
  title = {Establishing normal myocardial blood flow and myocardial flow reserve values: a rubidium-82 positron emission tomography study},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2026},
  volume = {53},
  number = {10},
  pages = {6075--6084},
  doi = {10.1007/s00259-026-07983-3}
}
Kostenlos starten →