Clinical evaluation of deep learning-based CT-free PET reconstruction image: a dual-center study
European Journal of Nuclear Medicine and Molecular Imaging · 2026-03 · 53 (4) · 2592-2603
DOI: 10.1007/s00259-025-07618-z ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 15.10.2025. Verfasst von Hangxing Chunyu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Deep Learning, Positron Emission Tomography Computed Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Shanghai Hospital Development Center Foundation, Science and Technology Commission of Shanghai Municipality (STCSM), National Natural Science Foundation of China.
Abstract (Originalsprache)
PURPOSE: Efforts to reduce the radiation burden of PET/CT have driven the increasing development of AI-based CT-less PET imaging techniques. However, comprehensive clinical evaluations of these approaches remain limited. This study aimed to rigorously assess whether deep learning (DL)-based PET reconstruction can eliminate the need for CT-derived attenuation and scatter correction while maintaining image quality sufficient for reliable clinical diagnosis. METHODS: In this dual-center retrospective analysis, raw PET/CT data from 359 patients were evaluated across 4 scanners and 4 tracers. Each dataset underwent four reconstruction approaches: (1) CT-based attenuation and scatter correction (CT-ASC, reference standard); (2) conventional 2D-DL; (3) conventional 3D-DL; and (4) our novel Decomposition-based DL algorithm. Diagnostic quality of reconstructed images was systematically assessed via visual scoring (5-point Likert scale), diagnostic accuracy (lesion-based false-positive/negative rates), and semi-quantitative metrics (SUVmax consistency). RESULTS: Visual analysis demonstrated the superior performance of Decomposition-based DL compared to conventional 2D-DL and 3D-DL (p < 0.001 for all comparisons). Furthermore, the proposed method exhibited the lowest false-negative and false-positive rates (0.56% false positives with SIEMENS Vision 600; zero rates in other cases). Semi-quantitative analysis showed that although Decomposition-based DL did not consistently yield the lowest mean absolute percentage error values compared to controls, it maintained strong agreement with CT-ASC in most cases. CONCLUSION: This dual-center study demonstrates that decomposition-based DL CT-free PET imaging outperforms conventional DL methods, achieving diagnostic accuracy comparable to CT-based attenuation correction in most cases. This clinical evaluation provides valuable insights to guide further methodological development and support clinical translation of CT-free PET imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiao Tong University, Shanghai, China.
- College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
- Department of Nuclear Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. gr11734@rjh.com.cn.
- Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiao Tong University, Shanghai, China. gr11734@rjh.com.cn.
ORCID-Profile: Biao Li
Förderung
- Shanghai Hospital Development Center Foundation
- Science and Technology Commission of Shanghai Municipality (STCSM)
- National Natural Science Foundation of China
- Natural Science Foundation of Shanghai
- Swiss National Science Foundation
Zitieren
APA
Chunyu, H., Chen, Y., Xue, S., Zhang, X., Miao, Y., Guo, R., Li, B., & Shi, K. (2026). Clinical evaluation of deep learning-based CT-free PET reconstruction image: a dual-center study. European Journal of Nuclear Medicine and Molecular Imaging, 53(4), 2592-2603. https://doi.org/10.1007/s00259-025-07618-z
Vancouver
Chunyu H, Chen Y, Xue S, Zhang X, Miao Y, Guo R, et al. Clinical evaluation of deep learning-based CT-free PET reconstruction image: a dual-center study. European Journal of Nuclear Medicine and Molecular Imaging. 2026;53(4):2592-2603. doi:10.1007/s00259-025-07618-z
BibTeX
@article{Chunyu2026,
author = {Chunyu, Hangxing and Chen, Yizhou and Xue, Song and Zhang, Xinyu and Miao, Ying and Guo, Rui and Li, Biao and Shi, Kuangyu},
title = {Clinical evaluation of deep learning-based CT-free PET reconstruction image: a dual-center study},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
volume = {53},
number = {4},
pages = {2592--2603},
doi = {10.1007/s00259-025-07618-z}
}
EUVIMED