Comparative Diagnostic Performance of Cone Beam Computed Tomography and Dual‐Energy X‐Ray Absorptiometry for Low Bone Density Assessment. A Systematic Review and Meta‐Analysis
Clinical and Experimental Dental Research · 2026
DOI: 10.1002/cre2.70423 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Clinical and Experimental Dental Research, 2026. Verfasst von Mohammad Alrashidi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai, UAE. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Bone Density, Absorptiometry, Photon, Osteoporosis. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
This systematic review evaluated the diagnostic accuracy of CBCT for BMD assessment using DEXA as the reference standard and aimed to quantify its performance through meta‐analysis. Materials and Methods This review included prospective and retrospective observational studies assessing CBCT's diagnostic performance in detecting low BMD, with DEXA as the reference. Searches in PubMed, Embase, and Scopus identified 13 eligible studies involving adult participants (≥ 18 years). Two reviewers independently extracted data and assessed study quality using the QUADAS‐2 tool. Meta‐analysis was conducted using random‐effects models.
Results
Pooled sensitivity and specificity of CBCT for detecting low BMD were 0.58 (95% CI: 0.50–0.67) and 0.78 (95% CI: 0.69–0.86), respectively. The summary receiver operating characteristic (SROC) curve showed an area under the curve (AUC) of 0.73 (95% CI: 0.69–0.77), indicating moderate diagnostic accuracy. Subgroup analyses revealed heterogeneity influenced by sample size and anatomical site.
Conclusion
CBCT demonstrates moderate diagnostic accuracy in detecting low BMD, with better specificity than sensitivity. While promising, standardization of CBCT protocols and larger studies are needed to confirm its role in clinical assessment. PROSPERO Registration Number (CRD42024598958).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai, UAE.
- School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK.
- The Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK.
- Faculty of Dentistry, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand.
- School of Dentistry, The University of Jordan, Amman, Jordan.
ORCID-Profile: Mohammad Alrashidi, Haitham Elbishari, May Aljanahi, Fatemeh Amir-Rad, Jahanzeb Chaudhry, Momen Atieh
Zitieren
APA
Alrashidi, M., Elbishari, H., Aljanahi, M., Amir-Rad, F., Chaudhry, J., & Atieh, M. (2026). Comparative Diagnostic Performance of Cone Beam Computed Tomography and Dual‐Energy X‐Ray Absorptiometry for Low Bone Density Assessment. A Systematic Review and Meta‐Analysis. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70423
Vancouver
Alrashidi M, Elbishari H, Aljanahi M, Amir-Rad F, Chaudhry J, Atieh M. Comparative Diagnostic Performance of Cone Beam Computed Tomography and Dual‐Energy X‐Ray Absorptiometry for Low Bone Density Assessment. A Systematic Review and Meta‐Analysis. Clinical and Experimental Dental Research. 2026. doi:10.1002/cre2.70423
BibTeX
@article{Alrashidi2026,
author = {Alrashidi, Mohammad and Elbishari, Haitham and Aljanahi, May and Amir-Rad, Fatemeh and Chaudhry, Jahanzeb and Atieh, Momen},
title = {Comparative Diagnostic Performance of Cone Beam Computed Tomography and Dual‐Energy X‐Ray Absorptiometry for Low Bone Density Assessment. A Systematic Review and Meta‐Analysis},
journal = {Clinical and Experimental Dental Research},
year = {2026},
doi = {10.1002/cre2.70423}
}
EUVIMED