EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Metal-artifact reduced MR imaging for reverse shoulder arthroplasty: findings 1 year after surgery

Pia M Jungmann, Martin Jaeger, Ferdinand C Wagner, Balazs Bogner, Arsenij Molotkov, Thierno Diallo, Ralph Strecker, Reto Sutter, Fabian Bamberg, Matthias Jung

Skeletal Radiology · 2026-05 · 55 (5) · 1087-1100

DOI: 10.1007/s00256-025-05121-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 21.01.2026. Verfasst von Pia M Jungmann und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstett…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Arthroplasty, Replacement, Shoulder, Artifacts, Metals. Die Arbeit nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Albert-Ludwigs-Universität Freiburg im Breisgau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To describe typical MRI findings 1 year after reverse total shoulder arthroplasty (rTSA) implantation. Materials and methods Metal artifact reduction (MARS) MRI including CSSEMAC techniques was prospectively acquired in N = 25 consecutive patients (18/25 female; 61–80 years) 1 year after rTSA. MRI findings of bone and soft tissue and artifact reduction were assessed semi-quantitatively. Clinical Constant-Murley scores (CMS) were obtained, including its subscores pain, activities-of-daily-living (ADL), range-of-motion (ROM), and strength. Preoperative MRI was available in 13/25 subjects. Statistical analyses included descriptive statistics, Spearman correlations, nonparametric tests, and multivariable regression models.

Results

MARS MRI of rTSA showed overall good image quality. Subacromial edema (88%), mild effusion (52%), and synovitis (44%) were frequent postoperative findings. Synovitis was associated with more pain ( B = −2.044, 95% CI [−3.617, −0.470], p = 0.039) and lower strength ( B = −4.497, 95% CI [−7.101, −1.893], p = 0.008). Minor bone marrow edema (BME) at the shaft was found in all subjects (100%). BME in Gruen zone 4 (88%) and 6 (80%) was most frequent. A higher number of Gruen zones with BME correlated significantly with lower ADL ( R = −0.532, p = 0.024). There was a significant increase in fatty infiltration between pre- and postoperative images for the midacromial deltoid muscle (1 (IQR, 1–1) versus 2 (IQR, 1–2), p = 0.008; postoperatively present 100%). It was associated with an increase in deltoid length (chi-square 4.35, p = 0.037), but not with inferior clinical scores. However, fatty infiltration of the more anterior deltoid muscle was associated with lower ADL ( B = −3.064, p = 0.008).

Conclusion

Subacromial edema, minor shaft BME, and fatty infiltration of the midacromial deltoid muscle were typical, asymptomatic MRI findings 1 year after rTSA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingArthroplasty, Replacement, ShoulderArtifactsMetalsPostoperative ComplicationsShoulder JointShoulder ProsthesisHumansFemaleMiddle AgedAgedAged, 80 and overMaleProspective Studies

Stichwörter der Autor:innen

ArthroplastyMagnetic resonance imaging (MRI)PostoperativeShoulder

Substanzen

Metals

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany. pia.baumann@ksgr.ch.
  • Department of Radiology, Kantonsspital Graubünden, Loëstrasse 170, 7000, Chur, Switzerland. pia.baumann@ksgr.ch.
  • Department of Orthopedics and Trauma Surgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
  • Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
  • EMEA Scientific Partnerships, Siemens Healthineers AG, Erlangen, Germany.
  • Department of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.

Förderung

  • Albert-Ludwigs-Universität Freiburg im Breisgau

Zitieren

APA

Jungmann, P. M., Jaeger, M., Wagner, F. C., Bogner, B., Molotkov, A., Diallo, T., Strecker, R., Sutter, R., Bamberg, F., & Jung, M. (2026). Metal-artifact reduced MR imaging for reverse shoulder arthroplasty: findings 1 year after surgery. Skeletal Radiology, 55(5), 1087-1100. https://doi.org/10.1007/s00256-025-05121-y

Vancouver

Jungmann PM, Jaeger M, Wagner FC, Bogner B, Molotkov A, Diallo T, et al. Metal-artifact reduced MR imaging for reverse shoulder arthroplasty: findings 1 year after surgery. Skeletal Radiology. 2026;55(5):1087-1100. doi:10.1007/s00256-025-05121-y

BibTeX
@article{Jungmann2026,
  author = {Jungmann, Pia M and Jaeger, Martin and Wagner, Ferdinand C and Bogner, Balazs and Molotkov, Arsenij and Diallo, Thierno and Strecker, Ralph and Sutter, Reto and Bamberg, Fabian and Jung, Matthias},
  title = {Metal-artifact reduced MR imaging for reverse shoulder arthroplasty: findings 1 year after surgery},
  journal = {Skeletal Radiology},
  year = {2026},
  volume = {55},
  number = {5},
  pages = {1087--1100},
  doi = {10.1007/s00256-025-05121-y}
}
Kostenlos starten →