Tornier Perform Anatomic Augmented Glenoid Implants correct posterior subluxation and maintain active joint reduction in Walch B2 glenoids
Journal of Shoulder and Elbow Surgery · 2025
DOI: 10.1016/j.jse.2025.02.047 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Kylie K Paliani und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Western University, London, ON, Canada; Roth | McFarlane Hand and Upper Limb Clinic, St. Joseph's Health Care, London, ON, Ca…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Dislocation, Shoulder Joint, Shoulder Prosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Stryker Corporation.
Abstract (Originalsprache)
BACKGROUND: The Walch type B2 glenoid is characterized by retroversion, posteroinferior erosion and posterior humeral head subluxation. A surgical management option for a B2 glenoid is an anatomic total shoulder arthroplasty (aTSA) with a posteriorly augmented all-posterior augmented glenoid (PAG) implant. However, little is known about what occurs actively at the glenohumeral articulation after aTSA with a PAG. Additionally, most studies on B2 glenoids, whether pre-aTSA or post-aTSA, assess subluxation statically. Presently, it is unknown if subluxation recurs after aTSA with a PAG or if it varies dynamically throughout active motion. Therefore, the primary objective of this study was to determine if Walch type B2 patients managed with an aTSA and a PAG (Tornier Perform Anatomic Augmented Glenoid Implant) would maintain correction of subluxation when examined statically and when stressed with active motion. The secondary objective was to analyze if a patient's range of motion (good or limited), magnitude of B2, or PAG implant size (15° or 25°) affect postoperative correction of subluxation. METHODS: Twenty Walch type B2 patients (mean age 68 years, range 54-83) underwent stemless aTSA with a 15° or 25° PAG implant and were assessed at a minimum 2-year follow-up. All patients underwent dynamic four-dimensional computed tomography scanning to actively track glenohumeral implant alignment and subluxation during a provocative active internal rotation (IR) motion protocol. Bone and implant 3D models of the humerus and scapula for each four-dimensional computed tomography scan were created using 3D Slicer. Landmarks were selected on the models to create coordinate systems that were then used in conjunction with a custom program (MATLAB) to determine subluxation preoperatively (statically), and postoperatively (dynamically). RESULTS: Posterior humeral head subluxation was significantly corrected (P .05) on subluxation postoperatively. CONCLUSION: At short-term follow-up, aTSA with an all-polyethylene PAG (Tornier Perform Anatomic Augmented Glenoid Implant) was successful at restoring and maintaining glenohumeral alignment with correction of subluxation throughout a provocative active IR motion protocol. As such, recurrence of subluxation does not occur statically or actively in patients who have undergone glenoid reconstruction with correction of posteroinferior erosion with a half-wedge PAG implant. Thus, aTSA with a PAG implant is an acceptable option for patients with mild or moderate B2 glenoids.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering, Western University, London, ON, Canada; Roth | McFarlane Hand and Upper Limb Clinic, St. Joseph's Health Care, London, ON, Canada. Electronic address: kpalian2@uwo.ca.
- Biomedical Engineering, Western University, London, ON, Canada; Roth | McFarlane Hand and Upper Limb Clinic, St. Joseph's Health Care, London, ON, Canada.
- Biomedical Engineering, Western University, London, ON, Canada; Roth | McFarlane Hand and Upper Limb Clinic, St. Joseph's Health Care, London, ON, Canada; Mechanical & Materials Engineering, Western University, London,…
- Robarts Research Institute, Western University, London, ON, Canada; Schulich School of Medicine & Dentistry, Western University, London, ON, Canada.
- Roth | McFarlane Hand and Upper Limb Clinic, St. Joseph's Health Care, London, ON, Canada; Schulich School of Medicine & Dentistry, Western University, London, ON, Canada.
Förderung
- Stryker Corporation
Zitieren
APA
Paliani, K. K., Hunter, J. C., Johnson, J. A., Lee, T. Y., Athwal, G. S., & Lalone, E. A. (2025). Tornier Perform Anatomic Augmented Glenoid Implants correct posterior subluxation and maintain active joint reduction in Walch B2 glenoids. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.02.047
Vancouver
Paliani KK, Hunter JC, Johnson JA, Lee TY, Athwal GS, Lalone EA. Tornier Perform Anatomic Augmented Glenoid Implants correct posterior subluxation and maintain active joint reduction in Walch B2 glenoids. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2025.02.047
BibTeX
@article{Paliani2025,
author = {Paliani, Kylie K and Hunter, James C and Johnson, James A and Lee, Ting-Yim and Athwal, George S and Lalone, Emily A},
title = {Tornier Perform Anatomic Augmented Glenoid Implants correct posterior subluxation and maintain active joint reduction in Walch B2 glenoids},
journal = {Journal of Shoulder and Elbow Surgery},
year = {2025},
doi = {10.1016/j.jse.2025.02.047}
}
EUVIMED