EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Scanogram leg length measurement after total hip arthroplasty: not all landmarks are created equal

Brian T N Le, Yoan Bourgeault-Gagnon, Matthew C Lyons, Samuel L McCaffrey, Lucy J Salmon, Michael D O'Sullivan

Skeletal Radiology · 2025

DOI: 10.1007/s00256-025-04895-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skeletal Radiology, 2025. Verfasst von Brian T N Le und 5 weiteren Autor:innen. Beteiligte Einrichtung: North Sydney Orthopaedic and Sports Medicine Centre, Suite 2 The Mater Clinic, 3 Gillies St, Wollstonecraft, Sydney, NSW, 2065, Australia. Hauptthemen laut MEDLINE: Leg Length Inequality, Tomography, X-Ray Computed, Arthroplasty, Replacement, Hip, Anatomic Landmarks. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Friends of The Mater Foundation, The University of Notre Dame Australia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the magnitude of post-arthroplasty leg length discrepancy (LLD) and incidence of clinically significant LLD measured on CT scanogram using a commonly used measurement method (from the acetabular apex to tibial plafond) to an alternative technique avoiding the use of the acetabular prosthesis as a landmark and to assess inter-observer and intra-rater reliability of the new technique. Materials and methods In this retrospective study, post-arthroplasty LLD measurements were conducted in 100 hips by two interpreters on CT scanogram scout views from the acetabular apex to the tibial plafond (AA-TP) and the inter-teardrop line to the tibial plafond (IT-TP). Aggregate means and proportions of clinically relevant LLD (≥ 10 mm) were compared between methods. Inter-rater reliability was calculated, and both interpreters repeated measurements on ten randomly selected patients to calculate intra-rater reliability.

Results

The commonly used AA-TP technique overestimated LLD by 3.7 mm compared to the IT-TP technique. The odds of LLD measurement exceeding the clinically significant threshold of 10 mm were 3.8 times higher when using the AA-TP technique. Excellent inter-rater (ICC 0.984, 0.958) and intra-rater reliability (ICC > 0.9) were found for both techniques.

Conclusion

CT scanogram measurements from the acetabular apex to the tibial plafond often overestimate operative limb length due to reference landmarks in different axial planes. Measurements from the inter-teardrop line to the tibial plafond yield significantly lower LLD values, possibly reflecting actual limb length better. The authors recommend using the inter-teardrop line and tibial plafond as reference landmarks to improve LLD assessment accuracy post-arthroplasty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Leg Length InequalityTomography, X-Ray ComputedArthroplasty, Replacement, HipAnatomic LandmarksPostoperative ComplicationsHumansRetrospective StudiesFemaleMaleReproducibility of ResultsAgedMiddle AgedAged, 80 and overObserver VariationAdult

Stichwörter der Autor:innen

Hip arthroplastyLeg lengthMeasurement techniqueRadiologyReliabilityScanogram

Autor:innen und Institutionen

  • North Sydney Orthopaedic and Sports Medicine Centre, Suite 2 The Mater Clinic, 3 Gillies St, Wollstonecraft, Sydney, NSW, 2065, Australia.
  • School of Medicine, University of Notre Dame, Sydney, Australia.
  • North Sydney Orthopaedic and Sports Medicine Centre, Suite 2 The Mater Clinic, 3 Gillies St, Wollstonecraft, Sydney, NSW, 2065, Australia. lsalmon@nsosmc.com.au.
  • School of Medicine, University of Notre Dame, Sydney, Australia. lsalmon@nsosmc.com.au.

Förderung

  • Friends of The Mater Foundation
  • The University of Notre Dame Australia

Zitieren

APA

Le, B. T. N., Bourgeault-Gagnon, Y., Lyons, M. C., McCaffrey, S. L., Salmon, L. J., & O'Sullivan, M. D. (2025). Scanogram leg length measurement after total hip arthroplasty: not all landmarks are created equal. Skeletal Radiology. https://doi.org/10.1007/s00256-025-04895-5

Vancouver

Le BTN, Bourgeault-Gagnon Y, Lyons MC, McCaffrey SL, Salmon LJ, O'Sullivan MD. Scanogram leg length measurement after total hip arthroplasty: not all landmarks are created equal. Skeletal Radiology. 2025. doi:10.1007/s00256-025-04895-5

BibTeX
@article{Le2025,
  author = {Le, Brian T N and Bourgeault-Gagnon, Yoan and Lyons, Matthew C and McCaffrey, Samuel L and Salmon, Lucy J and O'Sullivan, Michael D},
  title = {Scanogram leg length measurement after total hip arthroplasty: not all landmarks are created equal},
  journal = {Skeletal Radiology},
  year = {2025},
  doi = {10.1007/s00256-025-04895-5}
}
Kostenlos starten →