EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Managing hardware-related metal artifacts in MRI: current and evolving techniques

Georg C Feuerriegel, Reto Sutter

Skeletal Radiology · 2024-09 · 53 (9) · 1737-1750

DOI: 10.1007/s00256-024-04624-4 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Skeletal Radiology, online erschienen am 21.02.2024. Verfasst von Georg C Feuerriegel und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. georg.…. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Metals. Die Arbeit wurde bisher 67-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Zurich.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic resonance imaging (MRI) around metal implants has been challenging due to magnetic susceptibility differences between metal implants and adjacent tissues, resulting in image signal loss, geometric distortion, and loss of fat suppression. These artifacts can compromise the diagnostic accuracy and the evaluation of surrounding anatomical structures. As the prevalence of total joint replacements continues to increase in our aging society, there is a need for proper radiological assessment of tissues around metal implants to aid clinical decision-making in the management of post-operative complaints and complications. Various techniques for reducing metal artifacts in musculoskeletal imaging have been explored in recent years. One approach focuses on improving hardware components. High-density multi-channel radiofrequency (RF) coils, parallel imaging techniques, and gradient warping correction enable signal enhancement, image acquisition acceleration, and geometric distortion minimization. In addition, the use of susceptibility-matched implants and low-field MRI helps to reduce magnetic susceptibility differences. The second approach focuses on metal artifact reduction sequences such as view-angle tilting (VAT) and slice-encoding for metal artifact correction (SEMAC). Iterative reconstruction algorithms, deep learning approaches, and post-processing techniques are used to estimate and correct artifact-related errors in reconstructed images. This article reviews recent developments in clinically applicable metal artifact reduction techniques as well as advances in MR hardware. The review provides a better understanding of the basic principles and techniques, as well as an awareness of their limitations, allowing for a more reasoned application of these methods in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMagnetic Resonance ImagingMetalsHumansProstheses and Implants

Stichwörter der Autor:innen

ArthroplastyArtifactsJoint prosthesisMagnetic resonance imaging

Substanzen

Metals

Autor:innen und Institutionen

  • Department of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. georg.feuerriegel@balgrist.ch.
  • Department of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.

Förderung

  • University of Zurich

Zitieren

APA

Feuerriegel, G. C., & Sutter, R. (2024). Managing hardware-related metal artifacts in MRI: current and evolving techniques. Skeletal Radiology, 53(9), 1737-1750. https://doi.org/10.1007/s00256-024-04624-4

Vancouver

Feuerriegel GC, Sutter R. Managing hardware-related metal artifacts in MRI: current and evolving techniques. Skeletal Radiology. 2024;53(9):1737-1750. doi:10.1007/s00256-024-04624-4

BibTeX
@article{Feuerriegel2024,
  author = {Feuerriegel, Georg C and Sutter, Reto},
  title = {Managing hardware-related metal artifacts in MRI: current and evolving techniques},
  journal = {Skeletal Radiology},
  year = {2024},
  volume = {53},
  number = {9},
  pages = {1737--1750},
  doi = {10.1007/s00256-024-04624-4}
}
Kostenlos starten →