EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants—A Scanner Comparison Study

Alina Carolin Seifert, Hanns-Christian Breit, Felix Schlicht, Ricardo Donners, Dorothee Harder, Jan Vosshenrich

Academic Radiology · 2024

DOI: 10.1016/j.acra.2023.12.048 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Academic Radiology, 2024. Verfasst von Alina Carolin Seifert und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Metals, Prostheses and Implants. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: To compare image quality and metal artifact severity at 0.55 T and 1.5 T MRI in patients with spinal implants following posterior fusion surgery. MATERIALS AND METHODS: 50 consecutive patients (mean age: 69 ± 12 years) who underwent 0.55 T and 1.5 T MRI following posterior fusion surgery of the lumbar or thoracolumbar spine were included. Examinations used metal artifact reduction protocols from clinical routine. Images were rated by two fellowship-trained musculoskeletal radiologists for image quality, ability to assess the spinal canal and the neural foramina, and artifact severity on 5-point Likert scales. Additionally, differences in artifact severity and visibility of near-metal anatomy among implant sizes (1-level vs. 2-level vs. >2-levels) were evaluated. RESULTS: Signal/contrast (mean: 4.0 ± 0.3 [0.55 T] vs. 4.4 ± 0.6 [1.5 T]; p < .001) and resolution (3.8 ± 0.5 vs. 4.2 ± 0.7; p < .001) were rated lower at 0.55 T. The ability to assess the spinal canal (4.4 ± 0.5 vs. 4.2 ± 0.9; p = .69) and the neural foramina (3.8 ± 0.5 vs. 3.8 ± 0.9; p = .19) were however rated equally good with excellent interrater agreement (range: 0.84-0.94). Susceptibility artifacts were rated milder at 0.55 T (1.8 ± 0.5 vs. 3.0 ± 0.6; p < .001). For implant size-based subgroups, the visibility of near-metal anatomy decreased with implant length at 1.5 T, but remained unchanged at 0.55 T. In consequence, the spinal canal and neural foramina could be better assessed at 0.55 T in patients with multi-level implants (4.4 ± 0.5 vs. 3.6 ± 1.1; p < .001). CONCLUSION: Metal artifacts of spinal implants are substantially less pronounced at 0.55 T MRI. When examining patients with multi-level posterior fusion, this translates into a superior ability to assess near-metal anatomy, where 1.5 T MRI reaches diagnostic limitations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMagnetic Resonance ImagingMetalsProstheses and ImplantsHumansAgedFemaleMaleSpinal FusionMiddle Aged

Stichwörter der Autor:innen

ArtifactsLow-Field MRILumbar SpineMagnetic Resonance ImagingMetal

Substanzen

Metals

Autor:innen und Institutionen

  • Department of Radiology, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
  • Department of Radiology, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland. Electronic address: hanns-christian.breit@usb.ch.

Zitieren

APA

Seifert, A. C., Breit, H. C., Schlicht, F., Donners, R., Harder, D., & Vosshenrich, J. (2024). Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants—A Scanner Comparison Study. Academic Radiology. https://doi.org/10.1016/j.acra.2023.12.048

Vancouver

Seifert AC, Breit HC, Schlicht F, Donners R, Harder D, Vosshenrich J. Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants—A Scanner Comparison Study. Academic Radiology. 2024. doi:10.1016/j.acra.2023.12.048

BibTeX
@article{Seifert2024,
  author = {Seifert, Alina Carolin and Breit, Hanns-Christian and Schlicht, Felix and Donners, Ricardo and Harder, Dorothee and Vosshenrich, Jan},
  title = {Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants—A Scanner Comparison Study},
  journal = {Academic Radiology},
  year = {2024},
  doi = {10.1016/j.acra.2023.12.048}
}
Kostenlos starten →