Two-year experience of radiation dose watch for pediatric general fluoroscopic examinations
Pediatric Radiology · 2025
DOI: 10.1007/s00247-025-06183-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, 2025. Verfasst von Ronald A Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: University of Colorado Anschutz Medical Campus, 13001 E 17th Pl, Aurora, 80045, USA. Hauptthemen laut MEDLINE: Radiation Dosage, Radiation Monitoring. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The radiation dose of pediatric general fluoroscopy exams has historically been a topic of concern, with ongoing efforts and significant progress made. OBJECTIVE: The purpose of this study is to evaluate dose performance with a dose monitor program for pediatric general fluoroscopy. MATERIALS AND METHODS: Pediatric general fluoroscopy exams performed between April 1, 2020, and Dec. 31, 2022 were collected and monitored. For each exam, fluoroscopy time, dose-area-product (DAP), reference air kerma (RAK), and patient demographic information were analyzed. RAK, DAP, and fluoroscopy time were tested using Pearson's correlation methods for the three most frequently performed procedures. The influence of patient habitus on dose was studied using linear regression methods. Dose performance among radiologists was compared and so the Wilcoxon signed-rank test between radiologists with ≤ 5 years and > 5 years of experience post fellowship. A significance level of P 5 years' experience. CONCLUSION: Variations of pediatric general fluoroscopy dose performance were observed when comparing with other investigations. This study demonstrated that both patient size and operator experience influence radiation output in general fluoroscopy, factors that should be considered for pediatric fluoroscopy procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Colorado Anschutz Medical Campus, 13001 E 17th Pl, Aurora, 80045, USA.
- Children's Hospital Colorado, 13123 E 16th Ave, Aurora, 80045, USA.
- University of Colorado Anschutz Medical Campus, 13001 E 17th Pl, Aurora, 80045, USA. wei.zhou@CUanschutz.edu.
Zitieren
APA
Yang, R. A., Hayes, K., Milla, S. S., Dieselberg, S., & Zhou, W. (2025). Two-year experience of radiation dose watch for pediatric general fluoroscopic examinations. Pediatric Radiology. https://doi.org/10.1007/s00247-025-06183-9
Vancouver
Yang RA, Hayes K, Milla SS, Dieselberg S, Zhou W. Two-year experience of radiation dose watch for pediatric general fluoroscopic examinations. Pediatric Radiology. 2025. doi:10.1007/s00247-025-06183-9
BibTeX
@article{Yang2025,
author = {Yang, Ronald A and Hayes, Kari and Milla, Sarah S and Dieselberg, Shannan and Zhou, Wei},
title = {Two-year experience of radiation dose watch for pediatric general fluoroscopic examinations},
journal = {Pediatric Radiology},
year = {2025},
doi = {10.1007/s00247-025-06183-9}
}
EUVIMED