EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Scanner-based real-time three-dimensional brain + body slice-to-volume reconstruction for T2-weighted 0.55-T low-field fetal magnetic resonance imaging

Alena Uus, Sara Neves Silva, Jordina Aviles Verdera, Kelly Payette, Megan Hall, Kathleen Colford, Aysha Luis, Helena Sousa, Zihan Ning, Thomas Roberts, Sarah McElroy, Maria Deprez und 4 weitere

Pediatric Radiology · 24.01.2025 · 55 (3) · 556-569

DOI: 10.1007/s00247-025-06165-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Radiology, online erschienen am 24.01.2025. Verfasst von Alena Uus und 15 weiteren Autor:innen. Beteiligte Einrichtung: Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London,…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional, Brain, Prenatal Diagnosis. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Wellcome/EPSRC Centre for Medical Engineering, the Wellcome Trust, Sir Henry Fellowship, the UKRI FLF.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Motion correction methods based on slice-to-volume registration (SVR) for fetal magnetic resonance imaging (MRI) allow reconstruction of three-dimensional (3-D) isotropic images of the fetal brain and body. However, all existing SVR methods are confined to research settings, which limits clinical integration. Furthermore, there have been no reported SVR solutions for low-field 0.55-T MRI.

Objective

Integration of automated SVR motion correction methods directly into fetal MRI scanning process via the Gadgetron framework to enable automated T2-weighted (T2W) 3-D fetal brain and body reconstruction in the low-field 0.55-T MRI scanner within the duration of the scan. Materials and methods A deep learning fully automated pipeline was developed for T2W 3-D rigid and deformable (D/SVR) reconstruction of the fetal brain and body of 0.55-T T2W datasets. Next, it was integrated into 0.55-T low-field MRI scanner environment via a Gadgetron workflow that enables launching of the reconstruction process directly during scanning in real-time.

Results

During prospective testing on 12 cases (22–40 weeks gestational age), the fetal brain and body reconstructions were available on average 6:42 ± 3:13 min after the acquisition of the final stack and could be assessed and archived on the scanner console during the ongoing fetal MRI scan. The output image data quality was rated as good to acceptable for interpretation. The retrospective testing of the pipeline on 83 0.55-T datasets demonstrated stable reconstruction quality for low-field MRI.

Conclusion

The proposed pipeline allows scanner-based prospective T2W 3-D motion correction for low-field 0.55-T fetal MRI via direct online integration into the scanner environment. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImaging, Three-DimensionalBrainPrenatal DiagnosisHumansFemalePregnancyProspective StudiesDeep Learning

Stichwörter der Autor:innen

FetusImage reconstructionMagnetic resonance imagingReal-time

Autor:innen und Institutionen

  • Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK. alena.uus@kcl.ac.uk.
  • Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. alena.uus@kcl.ac.uk.
  • Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK.
  • Department of Women & Children's Health, King's College London, London, UK.
  • Clinical Scientific Computing, Guy's and St Thomas' NHS Foundation Trust, London, UK.
  • Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Förderung

  • the Wellcome/EPSRC Centre for Medical Engineering
  • the Wellcome Trust, Sir Henry Fellowship
  • the UKRI FLF
  • the NIHR Advanced Fellowship
  • the MRC
  • DFG Heisenberg the High Tech Agenda Bavaria

Zitieren

APA

Uus, A., Neves Silva, S., Aviles Verdera, J., Payette, K., Hall, M., Colford, K., Luis, A., Sousa, H., Ning, Z., Roberts, T., McElroy, S., Deprez, M., Hajnal, J., Rutherford, M., Story, L., & Hutter, J. (2025). Scanner-based real-time three-dimensional brain + body slice-to-volume reconstruction for T2-weighted 0.55-T low-field fetal magnetic resonance imaging. Pediatric Radiology, 55(3), 556-569. https://doi.org/10.1007/s00247-025-06165-x

Vancouver

Uus A, Neves Silva S, Aviles Verdera J, Payette K, Hall M, Colford K, et al. Scanner-based real-time three-dimensional brain + body slice-to-volume reconstruction for T2-weighted 0.55-T low-field fetal magnetic resonance imaging. Pediatric Radiology. 2025;55(3):556-569. doi:10.1007/s00247-025-06165-x

BibTeX
@article{Uus2025,
  author = {Uus, Alena and Neves Silva, Sara and Aviles Verdera, Jordina and Payette, Kelly and Hall, Megan and Colford, Kathleen and Luis, Aysha and Sousa, Helena and Ning, Zihan and Roberts, Thomas and McElroy, Sarah and Deprez, Maria and Hajnal, Joseph and Rutherford, Mary and Story, Lisa and Hutter, Jana},
  title = {Scanner-based real-time three-dimensional brain + body slice-to-volume reconstruction for T2-weighted 0.55-T low-field fetal magnetic resonance imaging},
  journal = {Pediatric Radiology},
  year = {2025},
  volume = {55},
  number = {3},
  pages = {556--569},
  doi = {10.1007/s00247-025-06165-x}
}
Kostenlos starten →