Can 3-dimensional cranial ultrasound be used to successfully reconstruct a 2-dimensional image without compromising on image quality in a neonatal population?

Rachel M Roberts iD, João Alves Rosa iD, Siân Curtis, Adam P R Smith-Collins, Martin Kidd, Savvas Andronikou iD

Pediatric Radiology · 2024

DOI: 10.1007/s00247-024-05886-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Radiology, 2024. Verfasst von Rachel M Roberts und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neuroradiology, West Wing Level 1, John Radcliffe Hospital, Headley Way, Headington, Oxford, OX3 9DU, UK. Rachel.roberts@ouh.nhs.uk. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal College of Radiologists.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cranial ultrasound is frequently performed in neonatal intensive care units and acquiring 2-dimensional (D) images requires significant training. Three-D ultrasound images can be acquired semi-automatically.

Objective

This proof-of-concept study aimed to demonstrate that 3-D study image quality compares well with 2-D. If this is successful, 3-D images could be acquired in remote areas and read remotely by experts. Materials and methods This was a prospective study of 20 neonates, who underwent both routine 2-D and 3-D cranial ultrasounds. Images were reconstructed into standard views extracted from the 3-D volume and evaluated by three radiologists blinded to the acquisition method. The radiologists assessed for the presence of anatomical landmarks and overall image quality.

Results

More anatomical structures were identified in the 3-D studies ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalHumansInfant, NewbornProspective StudiesFemaleMaleEchoencephalographyProof of Concept StudyIntensive Care Units, Neonatal

Stichwörter der Autor:innen

BrainImaging, three-dimensionalIntensive care units, neonatalNeonateUltrasonography

Autor:innen und Institutionen

  • Department of Neuroradiology, West Wing Level 1, John Radcliffe Hospital, Headley Way, Headington, Oxford, OX3 9DU, UK. Rachel.roberts@ouh.nhs.uk.
  • Neuroradiology Department, Southmead Hospital, North Bristol NHS Trust, Bristol, UK.
  • Department of Medical Physics & Bioengineering, St Michael's Hospital, Southwell Street, Bristol, UK.
  • Regional Neonatal Intensive Care Unit, St Michael's Hospital, Southwell Street, Bristol, UK.
  • Neonatal Neuroscience, University of Bristol Medical School, Southwell Street, Bristol, UK.
  • Centre for Statistical Consultation, Department of Statistics and Actuarial Sciences, University of Stellenbosch, Stellenbosch, South Africa.

ORCID-Profile: Rachel M Roberts, João Alves Rosa, Savvas Andronikou

Förderung

  • Royal College of Radiologists

Zitieren

APA

Roberts, R. M., Alves Rosa, J., Curtis, S., Smith-Collins, A. P. R., Kidd, M., & Andronikou, S. (2024). Can 3-dimensional cranial ultrasound be used to successfully reconstruct a 2-dimensional image without compromising on image quality in a neonatal population?. Pediatric Radiology. https://doi.org/10.1007/s00247-024-05886-9

Vancouver

Roberts RM, Alves Rosa J, Curtis S, Smith-Collins APR, Kidd M, Andronikou S. Can 3-dimensional cranial ultrasound be used to successfully reconstruct a 2-dimensional image without compromising on image quality in a neonatal population?. Pediatric Radiology. 2024. doi:10.1007/s00247-024-05886-9