EUVIMEDEUVIMED entdecken
Crossref

Fluid-attenuated inversion-recovery sequence with fat suppression as an alternative to contrast-enhanced MRI in pediatric synovitis

Kathryn S Milks iD, Jasmeet Singh, Jason A Benedict, Mitchell A Rees

Pediatric Radiology · 14.11.2023 · 54 (1) · 96-104

DOI: 10.1007/s00247-023-05804-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Radiology, online erschienen am 14.11.2023. Verfasst von Kathryn S Milks und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH, 43215, USA. ks.mueller@gmail.com. Hauptthemen laut MEDLINE: Contrast Media, Synovitis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Non-contrast magnetic resonance imaging (MRI) fluid-attenuated inversion-recovery sequence (FLAIR) with fat suppression (FS) has not been validated in children. OBJECTIVE: Compare FLAIR to T1-weighted post contrast (T1CE) in the detection of knee synovitis. METHODS AND MATERIALS: Institutional review board (IRB) waived consent. Children who underwent T1CE and FLAIR sequences of the knee on a 3-T magnet from April 2021 to December 2021 were included. Two pediatric radiologists assessed axial FLAIR and T1CE images for synovitis and synovial thickness. Reliability and agreement were assessed. Sensitivities, specificities, and accuracy were calculated for FLAIR using T1CE as reference standard. RESULTS: In total, 42 knees (39 patients) were assessed (median age 12.9 years (2.3-17.8 years); 62% male, 38% female). Readers judged 20/42 (48%) knees to have synovitis. Sensitivity of FLAIR for reader 1 was 79% (19/24; 95% CI 0.58, 0.93) and 84% (16/19; 95% CI 0.60, 0.97) for reader 2. Specificity of FLAIR for reader 1 was 94% (17/18; 95% CI 0.73, 1) and 83% (19/23; 95% CI 0.61, 0.95) for reader 2. Accuracy for readers 1 and 2 was 86% (36/42; 95% CI 0.71, 0.95) and 83% (35/42; 95% CI 0.69, 0.93), respectively. Inter-reader reliability was good (0.75-0.90) for synovial measurements for FLAIR (ICC = 0.80; 95% CI 0.71, 0.86) and moderate for T1 CE (ICC = 0.62 (95% CI 0.48, 0.73)). CONCLUSION: FLAIR FS depicts synovium in the pediatric knee with similar reliability to T1 CE and may be an acceptable alternative to contrast in the initial diagnosis of synovitis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaSynovitisHumansChildMaleFemaleReproducibility of ResultsMagnetic Resonance ImagingSynovial Membrane

Stichwörter der Autor:innen

FLAIRFat saturatedKneeMRIPediatricSynovitis

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH, 43215, USA. ks.mueller@gmail.com.
  • Department of Radiology, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH, 43215, USA.
  • Department of Biostatistics, The Ohio State University Wexner Medical Center, Columbus, OH, USA.

ORCID-Profile: Kathryn S Milks

Zitieren

APA

Milks, K. S., Singh, J., Benedict, J. A., & Rees, M. A. (2023). Fluid-attenuated inversion-recovery sequence with fat suppression as an alternative to contrast-enhanced MRI in pediatric synovitis. Pediatric Radiology, 54(1), 96-104. https://doi.org/10.1007/s00247-023-05804-5

Vancouver

Milks KS, Singh J, Benedict JA, Rees MA. Fluid-attenuated inversion-recovery sequence with fat suppression as an alternative to contrast-enhanced MRI in pediatric synovitis. Pediatric Radiology. 2023;54(1):96-104. doi:10.1007/s00247-023-05804-5

BibTeX
@article{Milks2023,
  author = {Milks, Kathryn S and Singh, Jasmeet and Benedict, Jason A and Rees, Mitchell A},
  title = {Fluid-attenuated inversion-recovery sequence with fat suppression as an alternative to contrast-enhanced MRI in pediatric synovitis},
  journal = {Pediatric Radiology},
  year = {2023},
  volume = {54},
  number = {1},
  pages = {96--104},
  doi = {10.1007/s00247-023-05804-5}
}
Kostenlos starten →