Percutaneous Device Closure of Perimembranous Ventricular Septal Defects Associated with Aortic Valve Prolapse and Aortic Regurgitation
Pediatric Cardiology · 2025
DOI: 10.1007/s00246-024-03725-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Cardiology, 2025. Verfasst von Ilker Kemal Yucel und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, University of Health Sciences Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital…. Hauptthemen laut MEDLINE: Heart Septal Defects, Ventricular, Aortic Valve Insufficiency, Septal Occluder Device, Aortic Valve Prolapse. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben.
Abstract (Originalsprache)
The progression of aortic regurgitation (AR) in perimembranous ventricular septal defects (pVSD) remains uncertain; research indicates that the accompanying AR tends to worsen over time. There is controversy surrounding the percutaneous closure of defects in patients with pVSD associated with aortic valve prolapse (AVP) and AR. Our research focused on transcatheter closure for pVSD accompanied by AVP, AR, and septal aneurysm, with the aim of addressing challenges through device placement in aneurysmal tissue to eliminate the Venturi effect. We studied 44 patients with AVP, AR, and septal aneurysm who underwent transcatheter device closure. The mean age and weight were 10.5 ± 4.0 years and 36.0 ± 15.1 kg, respectively. Transcatheter closure was attempted in 44 patients. One case (2.3%) was referred to surgery, while the procedure was successfully completed in 43 out of 44 patients (97.7%). Early complications were minimal. Embolization of the device to the pulmonary artery was observed in one patient; upon re-evaluation, significant aneurysm tissue damage was detected, leading to a referral for surgery. Additionally, three patients (6.9%) developed permanent incomplete right bundle branch block (iRBBB). The median follow-up time was 43 months. During the follow-up period, AR progressed in only 1(2.3%) patient, while AR in 7(16.3%) patients regressed markedly. Follow-up assessments demonstrated high rates of complete occlusion; the rates at immediate, 24 h, 6 months, and 1 year were assessed as 72, 83.7, 93, and 95.3%, respectively. Transcatheter device closure of pVSD offers a minimally invasive, safe, effective, and alternative treatment option for patients with pVSD associated with AVP and AR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, University of Health Sciences Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey. ilkerkemalyucel@yahoo.com.
- Department of Pediatric Cardiology, University of Health Sciences Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
Zitieren
APA
Yucel, I. K., Demir, I. H., Kardas, M., Bulut, M. O., Surucu, M., Yilmaz, E. H., Yekeler, R. I., & Celebi, A. (2025). Percutaneous Device Closure of Perimembranous Ventricular Septal Defects Associated with Aortic Valve Prolapse and Aortic Regurgitation. Pediatric Cardiology. https://doi.org/10.1007/s00246-024-03725-0
Vancouver
Yucel IK, Demir IH, Kardas M, Bulut MO, Surucu M, Yilmaz EH, et al. Percutaneous Device Closure of Perimembranous Ventricular Septal Defects Associated with Aortic Valve Prolapse and Aortic Regurgitation. Pediatric Cardiology. 2025. doi:10.1007/s00246-024-03725-0
BibTeX
@article{Yucel2025,
author = {Yucel, Ilker Kemal and Demir, Ibrahim Halil and Kardas, Murat and Bulut, M Orhan and Surucu, Murat and Yilmaz, E Hekim and Yekeler, R Irem and Celebi, Ahmet},
title = {Percutaneous Device Closure of Perimembranous Ventricular Septal Defects Associated with Aortic Valve Prolapse and Aortic Regurgitation},
journal = {Pediatric Cardiology},
year = {2025},
doi = {10.1007/s00246-024-03725-0}
}