Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
Pediatric Cardiology · 2023
DOI: 10.1007/s00246-023-03100-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Cardiology, 2023. Verfasst von Dhafer Alshahrani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Children's Health Ireland at Crumlin, Dublin 12, Republic of Ireland. Hauptthemen laut MEDLINE: Heart Septal Defects, Ventricular, Aortic Valve Insufficiency, Septal Occluder Device. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal College of Surgeons in Ireland.
Abstract (Originalsprache)
Transcatheter closure of Perimembranous VSDs (PMVSD) remains challenging particularly in infants. The aim of this study is to evaluate the efficacy and safety of transfemoral PMVSD device closure in infants weighing ≤ 10 kg in a single centre. Retrospective review of departmental databases and medical charts to define patient cohort and collect demographic, procedural and follow-up data. Between July 2014 and March 2021, 16 patients underwent attempted transfemoral PMVSD device closure (12 retrograde) at a median age of 11 months (interquartile range [IQR] 9–15.5) and a median weight of 8.3 kg (IQR 7.2–9.5). All patients were either symptomatic, had progressive left heart dilation or had VSD associated valve regurgitation. Median defect size on pre-procedural transoesophageal echocardiography was 6.8 mm (IQR 6–8.5). Median device waist size was 6 mm (IQR 4.5–8). Successful device placement was achieved in 14 patients (88%). One patient developed moderate aortic and tricuspid valve regurgitation upon retrograde and antegrade device deployment, respectively, and subsequently underwent surgical closure. The second patient developed progressive aortic regurgitation (AR) 2 days post procedure, and also underwent surgical removal with no residual AR. There was no cases of device embolization and no femoral arterial compromise. On median follow-up of 40.5 months (IQR 25–64), none of the patients developed complete heart block. Three patients (18.75%) had small residual shunts at latest follow-up which have not required any further intervention. Device closure of PMVSD’s in children weighing ≤ 10 kg is feasible and safe with good procedural success rates. Use of both the antegrade and retrograde approaches may be necessary depending on anatomical variances.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, Children's Health Ireland at Crumlin, Dublin 12, Republic of Ireland.
- Section of Pediatric Cardiology, Department of Cardiac Sciences, Ministry of National Guard Health Affairs, King Abdulaziz Medical City, Riyadh, Saudi Arabia.
- Department of Pediatric Cardiology, Royal Belfast Hospital of Sick Children, Belfast, UK.
- Department of Pediatric Cardiology, Children's Health Ireland at Crumlin, Dublin 12, Republic of Ireland. damien_kenny@icloud.com.
Förderung
- Royal College of Surgeons in Ireland
Zitieren
APA
Alshahrani, D., Linnane, N., McCrossan, B., Oslizlok, P., McMahon, C. J., Walsh, K. P., & Kenny, D. P. (2023). Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg. Pediatric Cardiology. https://doi.org/10.1007/s00246-023-03100-5
Vancouver
Alshahrani D, Linnane N, McCrossan B, Oslizlok P, McMahon CJ, Walsh KP, et al. Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg. Pediatric Cardiology. 2023. doi:10.1007/s00246-023-03100-5
BibTeX
@article{Alshahrani2023,
author = {Alshahrani, Dhafer and Linnane, Niall and McCrossan, Brian and Oslizlok, Paul and McMahon, Colin J and Walsh, Kevin P and Kenny, Damien P},
title = {Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg},
journal = {Pediatric Cardiology},
year = {2023},
doi = {10.1007/s00246-023-03100-5}
}