A sensitive and accurate method for determination of nitrofurans metabolites in food samples by ultra-high performance liquid chromatography-tandem mass spectrometry with a pair of facile isotope-coded derivatization reagents
Analytical and Bioanalytical Chemistry · 2026
DOI: 10.1007/s00216-026-06703-y ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, 2026. Verfasst von Xuedi Qi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Life-Organic Analysis of Shandong Province, Qufu Normal University, Qufu, 273165, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Nitrofurans, Food Contamination, Food Analysis. Die Arbeit nennt 47 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Consumption of food containing residues of nitrofuran metabolites may pose potential risks to human health. Although many countries have prohibited the use of nitrofurans as veterinary drugs, their illegal application persists. The detection of nitrofuran (NF) metabolites is essential for ensuring food safety. In this study, we designed and synthesized a pair of novel isotope-coded derivatization (ICD) reagents, 2-(4-formylphenyl)-1-phenyl-1H-naphtho[1,2-d]imidazole (d0-PPIB) and 2-(4-formylphenyl)-1-(pentadeuteriophenyl)-1H-naphtho[1,2-d]imidazole (d5-PPIB), using phenyl as the isotope-coded group. With the aid of the ICD reagents, a sensitive and accurate method for determination of NFs using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was established. The instrumental analysis time is remarkably short, with the four target analytes separated within just 4 min. The derivatization process was efficiently completed in only 15 min using microwave-assisted techniques, substantially reducing the overall experimental duration. The method achieved excellent sensitivity, with detection limits ranging from 0.011 to 0.019 μg/L, and the measurement error ranged from -2.2 to 3.5%. The intra- and inter-day precision was consistently high, with relative standard deviations (RSDs) below 5%. This ICD-based strategy effectively mitigates matrix effects while reducing costs and improving accuracy. Using one pair of ICD reagents (d0/d5-PPIB), multiple analytes are concurrently derivatized to generate their isotope-labeled internal standards, markedly decreasing commercial stable isotope-labeled (SIL) internal standard consumption. The method was successfully applied to quantify NF metabolites in three food samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Life-Organic Analysis of Shandong Province, Qufu Normal University, Qufu, 273165, China.
- Binzhou Experimental School, Binzhou, 256600, China.
- Key Laboratory of Life-Organic Analysis of Shandong Province, Qufu Normal University, Qufu, 273165, China. jizhongyin_730@163.com.
- School of Chemistry, Chemical Engineering and Materials, Jining University, Qufu, 273155, China. kongmhz@163.com.
- Key Laboratory of Life-Organic Analysis of Shandong Province, Qufu Normal University, Qufu, 273165, China. sunzhiw@126.com.
Förderung
- Natural Science Foundation of Shandong Province
Zitieren
APA
Qi, X., Xu, Z., Ji, Z., Kong, X., & Sun, Z. (2026). A sensitive and accurate method for determination of nitrofurans metabolites in food samples by ultra-high performance liquid chromatography-tandem mass spectrometry with a pair of facile isotope-coded derivatization reagents. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-026-06703-y
Vancouver
Qi X, Xu Z, Ji Z, Kong X, Sun Z. A sensitive and accurate method for determination of nitrofurans metabolites in food samples by ultra-high performance liquid chromatography-tandem mass spectrometry with a pair of facile isotope-coded derivatization reagents. Analytical and Bioanalytical Chemistry. 2026. doi:10.1007/s00216-026-06703-y
BibTeX
@article{Qi2026,
author = {Qi, Xuedi and Xu, Zenghui and Ji, Zhongyin and Kong, Xiaojian and Sun, Zhiwei},
title = {A sensitive and accurate method for determination of nitrofurans metabolites in food samples by ultra-high performance liquid chromatography-tandem mass spectrometry with a pair of facile isotope-coded derivatization reagents},
journal = {Analytical and Bioanalytical Chemistry},
year = {2026},
doi = {10.1007/s00216-026-06703-y}
}
EUVIMED