Determination of Acrylamide in Foods by Liquid Chromatography–Tandem Mass Spectrometry with a Porous Graphitic Carbon Column
Molecules · 04.11.2026 · 31 (21) · 3981
DOI: 10.3390/molecules31213981 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 04.11.2026. Verfasst von Huijiao Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical and Chemical Laboratory, Quanzhou Center for Disease Control and Prevention (Quanzhou Health Supervision Institute), Quanzhou …. Hauptthemen laut MEDLINE: Acrylamide, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Graphite. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Bureau of Quanzhou, Fujian Province Quanzhou City Science and Technology Project Funding.
Abstract (Originalsprache)
A high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was established for the determination of acrylamide in foods using a porous graphitic carbon (PGC) column for separation. Samples were spiked with an isotopically labeled internal standard, extracted with acetonitrile–water, purified using a mixed-mode cation-exchange (MCX) solid-phase extraction cartridge, and then separated on a PGC column. By employing a single-step pass-through MCX clean-up, the inherent anti-interference capacity of the PGC column in complex matrices was evaluated. Methanol and 0.1% formic acid in water served as the mobile phase, and detection was performed in positive electrospray ionization mode with multiple reaction monitoring (MRM). Method validation was conducted using meat products and coffee samples, and the method was further applied to eight sample categories (n = 68), including potato chips, biscuits, instant coffee, and local specialty foods from southern Fujian. Acrylamide exhibited good linearity over the concentration range of 10–500 µg/L, with correlation coefficients of 0.9994–0.9998. The limit of detection (LOD) was 0.81–1.38 µg/kg, and the limit of quantification (LOQ) was 2.70–4.61 µg/kg. The mean spiked recovery was 94.2–103.4%, with a relative standard deviation (RSD) of 0.8–5.4%, and the matrix effect was 60.6–76.5% for the PGC column, compared with 46.8–51.3% for the C18 column. A paired t-test showed that the PGC column exhibited a significantly higher matrix effect (ME) value (i.e., less signal suppression) than the C18 column (p < 0.05). Owing to the strong retention characteristics of the PGC column for polar compounds, the method effectively improves chromatographic separation and reduces co-eluting interferences. It provides a practical approach for reducing matrix interference and improving sensitivity in matrices where interferences are well-controlled (e.g., meat products), while effectively overcoming the overestimation of acrylamide in highly complex matrices like coffee, with a residual matrix effect corrected by the isotope-labeled internal standard specifically within these validated matrices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physical and Chemical Laboratory, Quanzhou Center for Disease Control and Prevention (Quanzhou Health Supervision Institute), Quanzhou 362000, China.
- The Affiliated Quanzhou Center for Disease Control and Prevention of Fujian Medical University, Quanzhou 362000, China.
ORCID-Profile: Weiping Xie
Förderung
- Science and Technology Bureau of Quanzhou
- Fujian Province Quanzhou City Science and Technology Project Funding
Zitieren
APA
Chen, H., Chen, L., & Xie, W. (2026). Determination of Acrylamide in Foods by Liquid Chromatography–Tandem Mass Spectrometry with a Porous Graphitic Carbon Column. Molecules, 31(21), 3981. https://doi.org/10.3390/molecules31213981
Vancouver
Chen H, Chen L, Xie W. Determination of Acrylamide in Foods by Liquid Chromatography–Tandem Mass Spectrometry with a Porous Graphitic Carbon Column. Molecules. 2026;31(21):3981. doi:10.3390/molecules31213981
BibTeX
@article{Chen2026,
author = {Chen, Huijiao and Chen, Lingang and Xie, Weiping},
title = {Determination of Acrylamide in Foods by Liquid Chromatography–Tandem Mass Spectrometry with a Porous Graphitic Carbon Column},
journal = {Molecules},
year = {2026},
volume = {31},
number = {21},
pages = {3981},
doi = {10.3390/molecules31213981}
}
EUVIMED