An integrated pH “Pen” for visual nucleic acid detection based on colorimetrical LAMP at point-of-care testing

Lei Wang, Zhifeng Wu, Jing Niu, Shangzhi Ji, Lulu Zhang, Michael G Mauk, Fang Li, Xianbo Qiu

Analytical and Bioanalytical Chemistry · 2025

DOI: 10.1007/s00216-025-06147-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Lei Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Information Science and Technology, Institute of Microfluidic Chip Development in Biomedical Engineering, Beijing University of Chemical T…. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Point-of-Care Testing, Colorimetry, Molecular Diagnostic Techniques. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nucleic acid detection serves as a critical tool employed for controlling the spread of infectious diseases. However, the majority of current nucleic acid detection methods still rely on large and complex equipment, rendering them unsuitable for point-of-care testing, particularly in remote or resource-limited areas. Therefore, the development of a simple, portable, and visual nucleic acid amplification and detection device is imperative. Based on the pH change during amplification in a non-buffered loop-mediated isothermal amplification (LAMP) system, we proposed an integrated pH "Pen" loaded with a pH test strip for endpoint detection of nucleic acid by naked eyes. The pH "Pen" was characterized by minimal instrumentation requirements, necessitating only a portable metal block for nucleic acid amplification. The device features a sealed chamber that ensures an accurate colorimetric response by preventing the pH test strip from contacting mineral oil, which is used to minimize reagent evaporation. Additionally, the image analysis method for assisted visual detection mitigates the impact of individual visual differences on color interpretation. By calculating the G/R value of the pH test strip image, this method enables the detection threshold to accommodate different imaging devices and lighting conditions. The non-viral OTU2m gene (a conserved gene derived from the Chlamydomonas reinhardtii strain) was chosen for proof of concept in our study. The "Pen" enabled the amplification and detection of the OTU2m gene within 28 min, with a limit of detection as low as 2.0 × 102 copies/mL, comparable to the sensitivity of the real-time fluorescence method. Given its simplicity, affordability, portability, and capacity for visual result analysis, the integrated pH "Pen" provided a promising method for nucleic acid detection at point-of-care testing, particularly in the condition with limited access to advanced laboratory infrastructure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesPoint-of-Care TestingColorimetryMolecular Diagnostic TechniquesNucleic AcidsHydrogen-Ion ConcentrationHumansLimit of Detection

Stichwörter der Autor:innen

Colorimetric assayImage analysisNucleic acid detectionPoint-of-care testingPortable devicesVisual detection

Substanzen

Nucleic Acids

Autor:innen und Institutionen

  • College of Information Science and Technology, Institute of Microfluidic Chip Development in Biomedical Engineering, Beijing University of Chemical Technology, Beijing, 100029, China.
  • College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China.
  • Beijing Wantai Biological Pharmacy Enterprise Co., Ltd., Beijing, 102299, China.
  • MEAM Department, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, 191045, USA.
  • College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China. lifang@mail.buct.edu.cn.
  • College of Information Science and Technology, Institute of Microfluidic Chip Development in Biomedical Engineering, Beijing University of Chemical Technology, Beijing, 100029, China. xbqiu@mail.buct.edu.cn.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Wang, L., Wu, Z., Niu, J., Ji, S., Zhang, L., Mauk, M. G., Li, F., & Qiu, X. (2025). An integrated pH “Pen” for visual nucleic acid detection based on colorimetrical LAMP at point-of-care testing. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-06147-w

Vancouver

Wang L, Wu Z, Niu J, Ji S, Zhang L, Mauk MG, et al. An integrated pH “Pen” for visual nucleic acid detection based on colorimetrical LAMP at point-of-care testing. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-06147-w

BibTeX
@article{Wang2025,
  author = {Wang, Lei and Wu, Zhifeng and Niu, Jing and Ji, Shangzhi and Zhang, Lulu and Mauk, Michael G and Li, Fang and Qiu, Xianbo},
  title = {An integrated pH “Pen” for visual nucleic acid detection based on colorimetrical LAMP at point-of-care testing},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  doi = {10.1007/s00216-025-06147-w}
}
Kostenlos starten →