EUVIMEDEUVIMED entdecken
Crossref

Development of a reverse transcription loop‐mediated isothermal amplification assay with novel quantitative p H biosensor readout method for SARS ‐ C o V ‐2 detection

Dian Ekayanti Astari iD, Muhammad Nasrum Massi, Rina Masadah, Marhaen Hardjo, Rosdiana Natzir, Michael Erlichster, Gursharan Chana, Efstratios Skafidas, Zeba Islam Seraj, Sabrina M Elias, Gita Vita Soraya iD

APMIS · 2024

DOI: 10.1111/apm.13415 ↗

Kurz gefasst

Fachartikel in der Zeitschrift APMIS, 2024. Verfasst von Dian Ekayanti Astari und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia. Hauptthemen laut MEDLINE: SARS-CoV-2, Nucleic Acid Amplification Techniques, COVID-19, Biosensing Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Islamic Development Bank, The World Academy of Sciences, Indonesian Endowment Fund for Education (LPDP) - RISPRO.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reverse transcription loop‐mediated isothermal amplification (RT‐LAMP) is a molecular amplification method that can detect SARS‐CoV‐2 in a shorter time than the current gold‐standard molecular diagnostic reverse transcription‐polymerase chain reaction (RT‐PCR). However, previously developed RT‐LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT‐LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID‐19 samples used for validation of the test. The LoD of the assay is 10 3 copies/μL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p < 0.0001) was observed between the average pH of the RT‐PCR (+) COVID‐19 (6.15 ± 0.27), while the average pH of the RT‐PCR (−) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p < 0.0001) between the Ct values obtained from RT‐PCR with the biosensor pH readout. RT‐LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS‐CoV‐2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2Nucleic Acid Amplification TechniquesCOVID-19Biosensing TechniquesSensitivity and SpecificityHumansHydrogen-Ion ConcentrationMolecular Diagnostic TechniquesColorimetryCOVID-19 Nucleic Acid TestingRNA, ViralLimit of Detection

Stichwörter der Autor:innen

COVID‐19RT‐LAMPSARS‐CoV‐2molecular diagnosticpH sensorpoint of care

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia.
  • Department of Biochemistry, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Department of Microbiology,Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Department of Pathology Anatomy, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • MX3 Diagnostics Inc., Melbourne, Victoria, Australia.
  • Department of Medicine, Royal Melbourne Hospital, The University of Melbourne, Melbourne, Victoria, Australia.

ORCID-Profile: Dian Ekayanti Astari, Gita Vita Soraya

Förderung

  • Islamic Development Bank
  • The World Academy of Sciences
  • Indonesian Endowment Fund for Education (LPDP) - RISPRO
  • Indonesian Ministry of Research and Technology (KEMENRISTEK-BRIN)
  • Lembaga Pengelola Dana Pendidikan

Zitieren

APA

Astari, D. E., Massi, M. N., Masadah, R., Hardjo, M., Natzir, R., Erlichster, M., Chana, G., Skafidas, E., Seraj, Z. I., Elias, S. M., & Soraya, G. V. (2024). Development of a reverse transcription loop‐mediated isothermal amplification assay with novel quantitative p H biosensor readout method for SARS ‐ C o V ‐2 detection. APMIS. https://doi.org/10.1111/apm.13415

Vancouver

Astari DE, Massi MN, Masadah R, Hardjo M, Natzir R, Erlichster M, et al. Development of a reverse transcription loop‐mediated isothermal amplification assay with novel quantitative p H biosensor readout method for SARS ‐ C o V ‐2 detection. APMIS. 2024. doi:10.1111/apm.13415

BibTeX
@article{Astari2024,
  author = {Astari, Dian Ekayanti and Massi, Muhammad Nasrum and Masadah, Rina and Hardjo, Marhaen and Natzir, Rosdiana and Erlichster, Michael and Chana, Gursharan and Skafidas, Efstratios and Seraj, Zeba Islam and Elias, Sabrina M and Soraya, Gita Vita},
  title = {Development of a reverse transcription loop‐mediated isothermal amplification assay with novel quantitative p H biosensor readout method for SARS ‐ C o V ‐2 detection},
  journal = {APMIS},
  year = {2024},
  doi = {10.1111/apm.13415}
}
Kostenlos starten →