EUVIMEDDescobrir EUVIMED
Open access · CC BY 4.0

An LC/MS/MS method for quantifying 25-hydroxyvitamin D3 in finger-prick plasma sample prepared by DEMECAL® micro plasma separation device: toward mail-in assessment of vitamin D status

Kodai Maeda, Kyoka Sakamoto, Eiko Ito, Shinya Sugimoto, Shingo Tajima, Takahisa Sasahara, Shunji Kawamura, Kazuo Yaegashi, Tatsuya Higashi

Analytical and Bioanalytical Chemistry · 2025

DOI: 10.1007/s00216-025-05939-4 ↗

At a glance

Journal article in Analytical and Bioanalytical Chemistry, 2025. Written by Kodai Maeda and 8 co-authors. Institution: Faculty of Pharmaceutical Sciences, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo, 125-8585, Japan. Major MEDLINE topics: Tandem Mass Spectrometry, Calcifediol, Blood Specimen Collection. Cited 2 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY 4.0). Funded by: Japan Society for the Promotion of Science, Tokyo University of Science.

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

A mail-in assessment of vitamin D status will make it possible for the subjects to early detect any vitamin D insufficiency/deficiency at their homes, thus leading to a better management of their health. In this study, a liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI–MS/MS) method was developed and validated for quantifying 25-hydroxyvitamin D 3 [25(OH)D 3 ], which is the established marker of the vitamin D status, in the finger-prick blood plasma sample prepared by the DEMECAL ® device. By using the DEMECAL ® device, the subjects can collect their finger-prick blood at their homes and immediately separate the plasma from the blood by themselves. The DEMECAL ® -based procedure had advantages over the venipuncture- and dried blood spot-based procedures because it is less invasive and a medical professional-free blood collection, and no need to be concerned with the heterogeneity of the analyte distribution in the sample. The developed LC/ESI–MS/MS method enabled the precise and accurate quantification of 25(OH)D 3 and provided the lower limit of quantification of 0.10 ng/mL in the diluted plasma sample due to the derivatization with 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione. 25(OH)D 3 was stable in the plasma sample prepared by the DEMECAL ® device at room temperature (23–27 °C) for 7 days (simulated condition in the mail) and at 4 °C for 30 days (simulated condition during storage at a laboratory). The measured 25(OH)D 3 concentrations by the DEMECAL ® -based procedure well agreed with those by the conventional venipuncture-based procedure. These results demonstrated that the derivatization-LC/ESI–MS/MS combined with the DEMECAL ® -based sample preparation is a promising procedure for the mail-in assessment of the vitamin D status. Graphical Abstract

Subjects

MeSH terms (MEDLINE)

Tandem Mass SpectrometryCalcifediolBlood Specimen CollectionHumansChromatography, LiquidLimit of DetectionReproducibility of ResultsPostal ServiceSpectrometry, Mass, Electrospray Ionization

Author keywords

DerivatizationFinger-prick bloodLC/ESI–MS/MSMicro plasma separationVitamin D status

Substances

Calcifediol

Authors and institutions

  • Faculty of Pharmaceutical Sciences, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo, 125-8585, Japan.
  • Leisure, Inc., 2-33-8 Nihombashi Ningyocho, Chuo-ku, Tokyo, 103-0013, Japan.
  • Itabashi Medical Laboratory, EIL, Inc., 2-20-10, Azusawa, Itabashi-ku, Tokyo, 174-0051, Japan.
  • Faculty of Pharmaceutical Sciences, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo, 125-8585, Japan. higashi@rs.tus.ac.jp.

Funding

  • Japan Society for the Promotion of Science
  • Tokyo University of Science

Cite

APA

Maeda, K., Sakamoto, K., Ito, E., Sugimoto, S., Tajima, S., Sasahara, T., Kawamura, S., Yaegashi, K., & Higashi, T. (2025). An LC/MS/MS method for quantifying 25-hydroxyvitamin D3 in finger-prick plasma sample prepared by DEMECAL® micro plasma separation device: toward mail-in assessment of vitamin D status. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-05939-4

Vancouver

Maeda K, Sakamoto K, Ito E, Sugimoto S, Tajima S, Sasahara T, et al. An LC/MS/MS method for quantifying 25-hydroxyvitamin D3 in finger-prick plasma sample prepared by DEMECAL® micro plasma separation device: toward mail-in assessment of vitamin D status. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-05939-4

BibTeX
@article{Maeda2025,
  author = {Maeda, Kodai and Sakamoto, Kyoka and Ito, Eiko and Sugimoto, Shinya and Tajima, Shingo and Sasahara, Takahisa and Kawamura, Shunji and Yaegashi, Kazuo and Higashi, Tatsuya},
  title = {An LC/MS/MS method for quantifying 25-hydroxyvitamin D3 in finger-prick plasma sample prepared by DEMECAL® micro plasma separation device: toward mail-in assessment of vitamin D status},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  doi = {10.1007/s00216-025-05939-4}
}