EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Comparison of the quantification performance of thermal desorption GC-IMS and GC-MS in VOC analysis

Hannah Schanzmann, Selina Gaar, Svenja Keip, Ursula Telgheder, Stefanie Sielemann

Analytical and Bioanalytical Chemistry · 2025-07 · 417 (18) · 4179-4198

DOI: 10.1007/s00216-025-05933-w ↗

At a glance

Journal article in Analytical and Bioanalytical Chemistry, published online on 2025-06-03. Written by Hannah Schanzmann and 4 co-authors. Institution: Laboratory of Applied Instrumental Analytical Chemistry, Hamm-Lippstadt University of Applied Sciences, Hamm, 59063, Germany. Cited 25 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: Bundesministerium für Bildung und Forschung, Hochschule Hamm-Lippstadt.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Accurate and reproducible quantification of volatile organic compounds (VOCs) is essential in environmental monitoring, clinical diagnostics, and quality control. Thermal desorption gas chromatography (TD-GC) is widely used for VOC analysis, often coupled with mass spectrometry (MS) for reliable identification. Ion mobility spectrometry (IMS) has gained attention for its high sensitivity and rapid detection. While GC-IMS and GC-MS are well established, TD-GC coupled to both IMS and MS has not been systematically investigated. This study presents a comprehensive assessment of a TD-GC-MS-IMS system, combining the strengths of both detectors. A mobile flow- and temperature-controlled sampling unit for TD tubes was developed for standardized applications, designed to introduce both gaseous and liquid samples. The long-term stability of TD-GC-IMS was assessed over 16 months with 156 measurement days using ketones. Relative standard deviations for signal intensities ranged from 3% to 13%, retention time deviations from 0.10% to 0.22%, and drift time deviations from 0.49% to 0.51%. Comparative evaluation showed IMS was approximately ten times more sensitive than MS, achieving limits of detections in the picogram/tube range. In contrast, MS exhibited a broader linear range, maintaining linearity over three orders of magnitude (up to 1000 ng/tube), while IMS retained linearity for one order of magnitude (e.g., 0.1 to 1 ng/tube for pentanal) before transitioning into a logarithmic response. To improve IMS quantification, a linearization strategy extended the calibration range from one to two orders of magnitude. These findings establish a standardized TD-GC-MS-IMS framework, improving reproducibility and comparability for clinical, environmental, and industrial VOC analysis.

Subjects

Author keywords

Limit of detection and quantificationLong-term stabilityPrecision studySample collectionTD-GC-MS-IMSThermal desorption tubes

Authors and institutions

  • Laboratory of Applied Instrumental Analytical Chemistry, Hamm-Lippstadt University of Applied Sciences, Hamm, 59063, Germany.
  • Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Essen, 45141, Germany.
  • Laboratory of Applied Instrumental Analytical Chemistry, Hamm-Lippstadt University of Applied Sciences, Hamm, 59063, Germany. stefanie.sielemann@hshl.de.

Funding

  • Bundesministerium für Bildung und Forschung
  • Hochschule Hamm-Lippstadt

Cite

APA

Schanzmann, H., Gaar, S., Keip, S., Telgheder, U., & Sielemann, S. (2025). Comparison of the quantification performance of thermal desorption GC-IMS and GC-MS in VOC analysis. Analytical and Bioanalytical Chemistry, 417(18), 4179-4198. https://doi.org/10.1007/s00216-025-05933-w

Vancouver

Schanzmann H, Gaar S, Keip S, Telgheder U, Sielemann S. Comparison of the quantification performance of thermal desorption GC-IMS and GC-MS in VOC analysis. Analytical and Bioanalytical Chemistry. 2025;417(18):4179-4198. doi:10.1007/s00216-025-05933-w

BibTeX
@article{Schanzmann2025,
  author = {Schanzmann, Hannah and Gaar, Selina and Keip, Svenja and Telgheder, Ursula and Sielemann, Stefanie},
  title = {Comparison of the quantification performance of thermal desorption GC-IMS and GC-MS in VOC analysis},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  volume = {417},
  number = {18},
  pages = {4179--4198},
  doi = {10.1007/s00216-025-05933-w}
}
Start for free →