A candidate reference measurement procedure for quantification of human insulin in serum based on immunoaffinity extraction and isotope dilution-liquid chromatography-tandem mass spectrometry
Analytical and Bioanalytical Chemistry · 2025
DOI: 10.1007/s00216-025-05900-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Huixia Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Insulin, Chromatography, Affinity. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Accurate measurement of human insulin is critical for proper diagnosis, monitoring, and treatment of diabetes. But the insulin results of clinical immunoassay are inconsistent mainly due to antibody cross-reactivity. To standardize and ensure the accuracy of clinical assays, reference measurement procedures (RMPs) with higher metrological order are required. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) for quantification of human insulin in serum as a candidate reference measurement procedure (cRMP) was developed and validated. Insulin was enriched from human serum by insulin antibodies immobilized on magnetic beads. The eluent was analyzed by ID-LC-MS/MS. The cRMP separated human insulin from potentially interfering compounds and enabled measurement over a range of 0.05-40 ng/g, with no matrix effects and carryover. The limit of detection (LOD) and the limit of quantitation (LOQ) in serum were 24.6 pg/g and 48.8 pg/g, respectively. Imprecision (intra-assay and inter-assay) was
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China.
- Department of Laboratory Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, Jiangsu, China.
- Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China. liangman@autobio.com.cn.
Zitieren
APA
Liu, H., Han, Y., Wang, H., Zhang, Y., Liu, C., & Liang, M. (2025). A candidate reference measurement procedure for quantification of human insulin in serum based on immunoaffinity extraction and isotope dilution-liquid chromatography-tandem mass spectrometry. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-05900-5
Vancouver
Liu H, Han Y, Wang H, Zhang Y, Liu C, Liang M. A candidate reference measurement procedure for quantification of human insulin in serum based on immunoaffinity extraction and isotope dilution-liquid chromatography-tandem mass spectrometry. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-05900-5