EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS

Elsa Boudard, Lisa Fisson, Nabil Moumane, José Dugay, Jérôme Vial, Didier Thiébaut

Analytical and Bioanalytical Chemistry · 2025-06 · 417 (14) · 3177-3190

DOI: 10.1007/s00216-025-05857-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 14.04.2025. Verfasst von Elsa Boudard und 5 weiteren Autor:innen. Beteiligte Einrichtung: UMR CBI, Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paris, PSL Research University, 10 rue Vauquelin, 75231, Pari…. Hauptthemen laut MEDLINE: Odorants, Gas Chromatography-Mass Spectrometry, Volatile Organic Compounds. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Association Nationale de la Recherche et de la Technologie, ESPCI Paris.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Body odor consists of a complex matrix of volatile organic compounds (VOCs), which has garnered increasing interest in fields like medicine for its potential in disease diagnosis. However, the field of body odor analysis is advancing slowly, partly due to a lack of standardized methodologies. Although gas chromatography–mass spectrometry (GC-MS) is widely used for VOC analysis, there is a broad range of sampling and extraction methods, leading to different or even sometimes contradictory results. To move toward standardized procedures, this study compares five sampling phases for direct body odor sampling in terms of analytical cleanliness and VOC trapping/release efficiency: gauze, glass beads, PowerSorb ® , Getxent ® microtubes, and passive sampling pillows (PSP). Thermodesorption was employed to simplify the protocol and minimize contamination or sample loss, which often occurs during multistep processes. Given the matrix’s complexity and the need to detect trace-level compounds, comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC/ToFMS) was used to achieve high sensitivity and peak capacity. PSP and PowerSorb ® demonstrated the best performance, with mean recovery yields of 95% and 71%, respectively, and 22% and 10% variability, ensuring good repeatability. These findings, initially obtained under simulated conditions with a synthetic mixture, were validated with real body odor samples, with an optimal sampling duration estimated between 30 min and 1 h. This study not only highlights these effective sampling solutions but also emphasizes the risks associated with using sorbent phases that lack adequate analytical cleanliness (i.e., clean blank) such as gauze. Graphical abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OdorantsGas Chromatography-Mass SpectrometryVolatile Organic CompoundsHumansReproducibility of ResultsLimit of Detection

Stichwörter der Autor:innen

Body odorBody volatolomeGC×GCSamplingVOCs

Substanzen

Volatile Organic Compounds

Autor:innen und Institutionen

  • UMR CBI, Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paris, PSL Research University, 10 rue Vauquelin, 75231, Paris, Cedex 05, France. elsa.boudard@espci.fr.
  • UMR CBI, Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paris, PSL Research University, 10 rue Vauquelin, 75231, Paris, Cedex 05, France.
  • SenseDetect Health-Care, 21 grande rue, 78240, Aigremont, France.

Förderung

  • Association Nationale de la Recherche et de la Technologie
  • ESPCI Paris

Zitieren

APA

Boudard, E., Fisson, L., Moumane, N., Dugay, J., Vial, J., & Thiébaut, D. (2025). Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS. Analytical and Bioanalytical Chemistry, 417(14), 3177-3190. https://doi.org/10.1007/s00216-025-05857-5

Vancouver

Boudard E, Fisson L, Moumane N, Dugay J, Vial J, Thiébaut D. Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS. Analytical and Bioanalytical Chemistry. 2025;417(14):3177-3190. doi:10.1007/s00216-025-05857-5

BibTeX
@article{Boudard2025,
  author = {Boudard, Elsa and Fisson, Lisa and Moumane, Nabil and Dugay, José and Vial, Jérôme and Thiébaut, Didier},
  title = {Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  volume = {417},
  number = {14},
  pages = {3177--3190},
  doi = {10.1007/s00216-025-05857-5}
}
Kostenlos starten →