Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS
Analytical and Bioanalytical Chemistry · 2025-06 · 417 (14) · 3177-3190
DOI: 10.1007/s00216-025-05857-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 14.04.2025. Verfasst von Elsa Boudard und 5 weiteren Autor:innen. Beteiligte Einrichtung: UMR CBI, Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paris, PSL Research University, 10 rue Vauquelin, 75231, Pari…. Hauptthemen laut MEDLINE: Odorants, Gas Chromatography-Mass Spectrometry, Volatile Organic Compounds. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Association Nationale de la Recherche et de la Technologie, ESPCI Paris.
Abstract (Originalsprache)
Body odor consists of a complex matrix of volatile organic compounds (VOCs), which has garnered increasing interest in fields like medicine for its potential in disease diagnosis. However, the field of body odor analysis is advancing slowly, partly due to a lack of standardized methodologies. Although gas chromatography–mass spectrometry (GC-MS) is widely used for VOC analysis, there is a broad range of sampling and extraction methods, leading to different or even sometimes contradictory results. To move toward standardized procedures, this study compares five sampling phases for direct body odor sampling in terms of analytical cleanliness and VOC trapping/release efficiency: gauze, glass beads, PowerSorb ® , Getxent ® microtubes, and passive sampling pillows (PSP). Thermodesorption was employed to simplify the protocol and minimize contamination or sample loss, which often occurs during multistep processes. Given the matrix’s complexity and the need to detect trace-level compounds, comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC/ToFMS) was used to achieve high sensitivity and peak capacity. PSP and PowerSorb ® demonstrated the best performance, with mean recovery yields of 95% and 71%, respectively, and 22% and 10% variability, ensuring good repeatability. These findings, initially obtained under simulated conditions with a synthetic mixture, were validated with real body odor samples, with an optimal sampling duration estimated between 30 min and 1 h. This study not only highlights these effective sampling solutions but also emphasizes the risks associated with using sorbent phases that lack adequate analytical cleanliness (i.e., clean blank) such as gauze. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- UMR CBI, Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paris, PSL Research University, 10 rue Vauquelin, 75231, Paris, Cedex 05, France. elsa.boudard@espci.fr.
- UMR CBI, Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paris, PSL Research University, 10 rue Vauquelin, 75231, Paris, Cedex 05, France.
- SenseDetect Health-Care, 21 grande rue, 78240, Aigremont, France.
Förderung
- Association Nationale de la Recherche et de la Technologie
- ESPCI Paris
Zitieren
APA
Boudard, E., Fisson, L., Moumane, N., Dugay, J., Vial, J., & Thiébaut, D. (2025). Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS. Analytical and Bioanalytical Chemistry, 417(14), 3177-3190. https://doi.org/10.1007/s00216-025-05857-5
Vancouver
Boudard E, Fisson L, Moumane N, Dugay J, Vial J, Thiébaut D. Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS. Analytical and Bioanalytical Chemistry. 2025;417(14):3177-3190. doi:10.1007/s00216-025-05857-5
BibTeX
@article{Boudard2025,
author = {Boudard, Elsa and Fisson, Lisa and Moumane, Nabil and Dugay, José and Vial, Jérôme and Thiébaut, Didier},
title = {Study of sampling phases for body odor sampling prior to analysis by TD-GC×GC/ToFMS},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
volume = {417},
number = {14},
pages = {3177--3190},
doi = {10.1007/s00216-025-05857-5}
}
EUVIMED