Interference of the gas chromatography- mass spectrometry instrumental background on the determination of trace cyclic volatile methylsiloxanes and exclusion of it by delayed injection
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2024.464894 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Guoliang Huang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology of Ministry of Education, …. Hauptthemen laut MEDLINE: Siloxanes, Gas Chromatography-Mass Spectrometry, Limit of Detection. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Hangzhou Normal University, Natural Science Foundation of Zhejiang Province.
Abstract (Originalsprache)
Cyclic volatile methylsiloxanes (cVMS) have been widely found in various types of environmental media and attracted increasing attention as new pollutants. However, there is still a great challenge in the accurate quantification of trace cVMS, due to their volatility, and the high background originating from GC/MS accessories and surroundings. In this work, the main sources of the high background were investigated in detail for octamethylcyclotetrasiloxane (D4), decmethylcyclopentasiloxane (D5) and dodecmethylcyclohexosiloxane (D6). Several effective measures were employed to minimize these backgrounds, including the delayed injection method to minimize the interference from the injection septum. Then, a GC-MS method was developed for the accurate determination of D4, D5 and D6, with a linear range of 2 - 200 μg/L. The coefficient of determination was 0.9982-0.9986, the limit of detection (LOD) was 0.40-0.52 μg/L, and the quantitative range was 1.88-190 μg/L. Good reproducibility and recovery were obtained, indicating the reliability of the established analytical method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology of Ministry of Education, Hangzhou Normal University, Yuhangtang Road 2318, Yuhang District, Han…
- Zhejiang Key Laboratory of Ecological and Environmental Monitoring, Forewarning and Quality Control, Zhejiang Ecological and Environmental Monitoring Center, Xueyuan Road 117, Xihu District, Hangzhou, China. Electronic…
Förderung
- Hangzhou Normal University
- Natural Science Foundation of Zhejiang Province
Zitieren
APA
Huang, G., Li, Y., Liu, J., Jiang, D., & Jiang, K. (2024). Interference of the gas chromatography- mass spectrometry instrumental background on the determination of trace cyclic volatile methylsiloxanes and exclusion of it by delayed injection. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.464894
Vancouver
Huang G, Li Y, Liu J, Jiang D, Jiang K. Interference of the gas chromatography- mass spectrometry instrumental background on the determination of trace cyclic volatile methylsiloxanes and exclusion of it by delayed injection. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.464894
BibTeX
@article{Huang2024,
author = {Huang, Guoliang and Li, Yunna and Liu, Jinsong and Jiang, Duohao and Jiang, Kezhi},
title = {Interference of the gas chromatography- mass spectrometry instrumental background on the determination of trace cyclic volatile methylsiloxanes and exclusion of it by delayed injection},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2024.464894}
}
EUVIMED