EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Leveraging the potential of 1.0-mm i.d. columns in UHPLC-HRMS-based untargeted metabolomics

Danila La Gioia, Emanuela Salviati, Manuela Giovanna Basilicata, Claudia Felici, Oronza A Botrugno, Giovanni Tonon, Eduardo Sommella, Pietro Campiglia

Analytical and Bioanalytical Chemistry · 2025-05 · 417 (13) · 2837-2847

DOI: 10.1007/s00216-024-05588-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 24.10.2024. Verfasst von Danila La Gioia und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084, Fisciano, SA, Italy. Hauptthemen laut MEDLINE: Metabolomics, Mass Spectrometry. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero dell'Istruzione, dell'Università e della Ricerca, Ministero dell’Istruzione, dell’Università e della Ricerca.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Untargeted metabolomics UHPLC-HRMS workflows typically employ narrowbore 2.1-mm inner diameter (i.d.) columns. However, the wide concentration range of the metabolome and the need to often analyze small sample amounts poses challenges to these approaches. Reducing the column diameter could be a potential solution. Herein, we evaluated the performance of a microbore 1.0-mm i.d. setup compared to the 2.1-mm i.d. benchmark for untargeted metabolomics. The 1.0-mm i.d. setup was implemented on a micro-UHPLC system, while the 2.1-mm i.d. on a standard UHPLC, both coupled to quadrupole-orbitrap HRMS. On polar standard metabolites, a sensitivity gain with an average 3.8-fold increase over the 2.1-mm i.d., along with lower LOD (LOD avg 1.48 ng/mL vs. 6.18 ng/mL) and LOQ (LOQ avg 4.94 ng/mL vs. 20.60 ng/mL), was observed. The microbore method detected and quantified all metabolites at LLOQ with respect to 2.1, also demonstrating good repeatability with lower CV% for retention times (0.29% vs. 0.63%) and peak areas (4.65% vs. 7.27%). The analysis of various samples, in both RP and HILIC modes, including different plasma volumes, dried blood spots (DBS), and colorectal cancer (CRC) patient-derived organoids (PDOs), in full scan-data dependent mode (FS-DDA) reported a significant increase in MS1 and MS2 features, as well as MS/MS spectral matches by 38.95%, 39.26%, and 18.23%, respectively. These findings demonstrate that 1.0-mm i.d. columns in UHPLC-HRMS could be a potential strategy to enhance coverage for low-amount samples while maintaining the same analytical throughput and robustness of 2.1-mm i.d. formats, with reduced solvent consumption.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetabolomicsMass SpectrometryChromatography, High Pressure LiquidHumansLimit of DetectionReproducibility of Results

Stichwörter der Autor:innen

Mass spectrometryMetabolomicsMicroboreUHPLCUntargeted

Autor:innen und Institutionen

  • Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084, Fisciano, SA, Italy.
  • PhD Program in Drug Discovery and Development, University of Salerno, Fisciano, SA, Italy.
  • Department of Advanced Medical and Surgical Sciences, University of Campania "Luigi Vanvitelli", 80138, Naples, Italy.
  • Functional Genomics of Cancer Unit, Division of Experimental Oncology, IRCCS San Raffaele Scientific Institute, Milan, Italy.
  • Vita-Salute San Raffaele University, Milan, Italy.
  • Center for Omics Sciences, IRCCS San Raffaele Scientific Institute, Milan, Italy.

Förderung

  • Ministero dell'Istruzione, dell'Università e della Ricerca
  • Ministero dell’Istruzione, dell’Università e della Ricerca

Zitieren

APA

La Gioia, D., Salviati, E., Basilicata, M. G., Felici, C., Botrugno, O. A., Tonon, G., Sommella, E., & Campiglia, P. (2025). Leveraging the potential of 1.0-mm i.d. columns in UHPLC-HRMS-based untargeted metabolomics. Analytical and Bioanalytical Chemistry, 417(13), 2837-2847. https://doi.org/10.1007/s00216-024-05588-z

Vancouver

La Gioia D, Salviati E, Basilicata MG, Felici C, Botrugno OA, Tonon G, et al. Leveraging the potential of 1.0-mm i.d. columns in UHPLC-HRMS-based untargeted metabolomics. Analytical and Bioanalytical Chemistry. 2025;417(13):2837-2847. doi:10.1007/s00216-024-05588-z

BibTeX
@article{LaGioia2025,
  author = {La Gioia, Danila and Salviati, Emanuela and Basilicata, Manuela Giovanna and Felici, Claudia and Botrugno, Oronza A and Tonon, Giovanni and Sommella, Eduardo and Campiglia, Pietro},
  title = {Leveraging the potential of 1.0-mm i.d. columns in UHPLC-HRMS-based untargeted metabolomics},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  volume = {417},
  number = {13},
  pages = {2837--2847},
  doi = {10.1007/s00216-024-05588-z}
}