Quantifying the extended energy metabolome of industrially important microorganisms (Saccharomyces cerevisiae) using ultra-performance liquid chromatography with mass spectrometry
Journal of Chromatography B · 2024
DOI: 10.1016/j.jchromb.2024.124342 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography B, 2024. Verfasst von Jordan I Oliver und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sustainable Environment Research Centre, University of South Wales, Pontypridd, Wales, United Kingdom. Electronic address: jordan.oliver@southwales.a…. Hauptthemen laut MEDLINE: Saccharomyces cerevisiae, Metabolome, Mass Spectrometry, Limit of Detection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Welsh Government, University of South Wales, Royal Academy of Engineering.
Abstract (Originalsprache)
This study has developed a new targeted methodology for the separation, detection, and quantification of metabolites from the wider energy metabolome of industrially important microorganisms such as Saccharomyces cerevisiae in a single analytical sample. This has been achieved using UHPLC-MS technology in HILIC mode. Absolute concentrations of metabolites nicotinamide adenine dinucleotide (NAD), nicotinamide adenine dinucleotide reduced (NADH), nicotinamide adenine dinucleotide phosphate (NADP), nicotinamide adenine dinucleotide phosphate reduced (NADPH), flavin adenine dinucleotide (FAD), adenosine-monophosphate (AMP), adenosine-diphosphate (ADP), and adenosine-triphosphate (ATP) were determined in a single extraction and analytical methodology. This study demonstrated the development of a rapid, statistically robust, and reproducible methodology through regression calibrations of standard samples from 0.1 to 100 µMol providing a correlation value of r2 = >0.98 for all metabolites. Sample preparation, extraction and analytical methodologies used showed high accuracy, sensitivity, and recovery. With an LOD and LOQ for the targeted analysis of metabolites from the wider energy metabolism in a single sample and analytical run with the lowest LOD of 0.055 nMol (±0.002) and lowest LOQ of 0.167 nMol (±0.006). This method was then applied to Saccharomyces cerevisiae cell culture to evaluate the methodology in industrially used microbial cultures. Results obtained have been statistically determined to be robust and reproducible through recovery analysis using deuterated and isotopically labelled internal standards AMP-15N, ADP-15N and ATP-d14.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sustainable Environment Research Centre, University of South Wales, Pontypridd, Wales, United Kingdom. Electronic address: jordan.oliver@southwales.ac.uk.
- Sustainable Environment Research Centre, University of South Wales, Pontypridd, Wales, United Kingdom.
Förderung
- Welsh Government
- University of South Wales
- Royal Academy of Engineering
Zitieren
APA
Oliver, J. I., Davies, A. N., & Dinsdale, R. (2024). Quantifying the extended energy metabolome of industrially important microorganisms (Saccharomyces cerevisiae) using ultra-performance liquid chromatography with mass spectrometry. Journal of Chromatography B. https://doi.org/10.1016/j.jchromb.2024.124342
Vancouver
Oliver JI, Davies AN, Dinsdale R. Quantifying the extended energy metabolome of industrially important microorganisms (Saccharomyces cerevisiae) using ultra-performance liquid chromatography with mass spectrometry. Journal of Chromatography B. 2024. doi:10.1016/j.jchromb.2024.124342
BibTeX
@article{Oliver2024,
author = {Oliver, Jordan I and Davies, Antony N and Dinsdale, Richard},
title = {Quantifying the extended energy metabolome of industrially important microorganisms (Saccharomyces cerevisiae) using ultra-performance liquid chromatography with mass spectrometry},
journal = {Journal of Chromatography B},
year = {2024},
doi = {10.1016/j.jchromb.2024.124342}
}
EUVIMED