New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma
Analytical and Bioanalytical Chemistry · 2025-03 · 417 (7) · 1293-1303
DOI: 10.1007/s00216-024-05503-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 29.08.2024. Verfasst von Chenchen Song und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway. Hauptthemen laut MEDLINE: Membranes, Artificial, Acids, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Oslo.
Abstract (Originalsprache)
The current paper reports two new, robust, and efficient conditions for electromembrane extraction of acidic substances from human plasma. Two systems were developed based on eutectic solvents: A1 (“A” for acid) comprised dodecyl methyl sulfoxide and thymol in 1:2 ratio (w/w) as liquid membrane, while A2 used [6-methylcoumarin:thymol (1:2)]:2-nitrophenyl octyl ether in 2:1 ratio (w/w). The performance of A1 and A2 was characterized by extraction of 31 acidic model analytes (pharmaceutical drugs and nutrients) spiked into 100 µL human plasma diluted 1:1 (v/v) with phosphate buffer pH 7.4. The acceptor solution was 50 mM NH 4 HCO 3 buffer pH 10.0, and extraction was performed at an agitation rate of 750 RPM. Voltage and extraction time were 30 V for 30 min and 10 V for 20 min for A1 and A2, respectively. Under optimal conditions, A1 extracted analytes with 1.8 ≤ log P ≤ 6.0 with an average recovery ( R ) of 85.1%, while A2 extracted in a range of 0.5 ≤ log P ≤ 6.0 with an average recovery of 79.9%. Meanwhile, extraction current was low at 9 and 26 µA, respectively, which is indicative of good system robustness. Using UHPLC-MS/MS analysis of the acceptor solution, repeatability of the A1 and A2 methods was determined to be 2.8–7.7% and 3.3–9.4% for R > 40%, matrix effects were 82–117% and 84–112%, respectively, and linear calibration curves were obtained. The performance and compatibility with human plasma represent a major improvement over previous state-of-the-art liquid membranes for acidic analytes, namely 1-octanol. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway.
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, China.
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway. f.a.hansen@farmasi.uio.no.
Förderung
- University of Oslo
Zitieren
APA
Song, C., Dowlatshah, S., Gaznawi, S., Hay, A. O., Hasvold, G., & Hansen, F. A. (2025). New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma. Analytical and Bioanalytical Chemistry, 417(7), 1293-1303. https://doi.org/10.1007/s00216-024-05503-6
Vancouver
Song C, Dowlatshah S, Gaznawi S, Hay AO, Hasvold G, Hansen FA. New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma. Analytical and Bioanalytical Chemistry. 2025;417(7):1293-1303. doi:10.1007/s00216-024-05503-6
BibTeX
@article{Song2025,
author = {Song, Chenchen and Dowlatshah, Samira and Gaznawi, Somayeh and Hay, Anne Oldeide and Hasvold, Grete and Hansen, Frederik André},
title = {New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
volume = {417},
number = {7},
pages = {1293--1303},
doi = {10.1007/s00216-024-05503-6}
}
EUVIMED