EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Self-powered wearable biosensor based on stencil-printed carbon nanotube electrodes for ethanol detection in sweat

Verdiana Marchianò, Angelo Tricase, Eleonora Macchia, Paolo Bollella, Luisa Torsi

Analytical and Bioanalytical Chemistry · 2024-10 · 416 (24) · 5303-5316

DOI: 10.1007/s00216-024-05467-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 12.08.2024. Verfasst von Verdiana Marchianò und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy-Pharmaceutical Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Biosensing Techniques, Ethanol, Wearable Electronic Devices. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Regione Puglia, Ministry of Agriculture, Food Sovereignty and Forests, European Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Herein we introduce a novel water-based graphite ink modified with multiwalled carbon nanotubes, designed for the development of the first wearable self-powered biosensor enabling alcohol abuse detection through sweat analysis. The stencil-printed graphite (SPG) electrodes, printed onto a flexible substrate, were modified by casting multiwalled carbon nanotubes (MWCNTs), electrodepositing polymethylene blue (pMB) at the anode to serve as a catalyst for nicotinamide adenine dinucleotide (NADH) oxidation, and hemin at the cathode as a selective catalyst for H 2 O 2 reduction. Notably, alcohol dehydrogenase (ADH) was additionally physisorbed onto the anodic electrode, and alcohol oxidase (AOx) onto the cathodic electrode. The self-powered biosensor was assembled using the ADH/pMB-MWCNTs/SPG||AOx/Hemin-MWCNTs/SPG configuration, enabling the detection of ethanol as an analytical target, both at the anodic and cathodic electrodes. Its performance was assessed by measuring polarization curves with gradually increasing ethanol concentrations ranging from 0 to 50 mM. The biosensor demonstrated a linear detection range from 0.01 to 0.3 mM, with a detection limit (LOD) of 3 ± 1 µM and a sensitivity of 64 ± 2 μW mM −1 , with a correlation coefficient of 0.98 (RSD 8.1%, n = 10 electrode pairs). It exhibited robust operational stability (over 2800 s with continuous ethanol turnover) and excellent storage stability (approximately 93% of initial signal retained after 90 days). Finally, the biosensor array was integrated into a wristband and successfully evaluated for continuous alcohol abuse monitoring. This proposed system displays promising attributes for use as a flexible and wearable biosensor employing biocompatible water-based inks, offering potential applications in forensic contexts. Graphical Abstract A novel water-based graphite ink modified with multiwalled carbon nanotubes designed for the development of a wearable self-powered biosensor enabling alcohol abuse detection through sweat analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nanotubes, CarbonBiosensing TechniquesEthanolWearable Electronic DevicesSweatElectrodesLimit of DetectionHumansAlcohol DehydrogenaseElectrochemical TechniquesGraphiteAlcohol Oxidoreductases

Stichwörter der Autor:innen

Enzymatic biofuel cellsEthanol biosensorsModified electrodesWater-based conductive inksWearable biosensors

Substanzen

Nanotubes, CarbonEthanolAlcohol DehydrogenaseGraphiteAlcohol Oxidoreductasesalcohol oxidase

Autor:innen und Institutionen

  • Department of Pharmacy-Pharmaceutical Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy.
  • Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy.
  • Faculty of Science and Engineering, Åbo Akademi University, 20500, Turku, Finland.
  • Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy. paolo.bollella@uniba.it.
  • Department of Chemistry, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy. paolo.bollella@uniba.it.
  • Department of Chemistry, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy.

Förderung

  • Regione Puglia
  • Ministry of Agriculture, Food Sovereignty and Forests
  • European Research Council
  • Università degli Studi di Bari Aldo Moro

Zitieren

APA

Marchianò, V., Tricase, A., Macchia, E., Bollella, P., & Torsi, L. (2024). Self-powered wearable biosensor based on stencil-printed carbon nanotube electrodes for ethanol detection in sweat. Analytical and Bioanalytical Chemistry, 416(24), 5303-5316. https://doi.org/10.1007/s00216-024-05467-7

Vancouver

Marchianò V, Tricase A, Macchia E, Bollella P, Torsi L. Self-powered wearable biosensor based on stencil-printed carbon nanotube electrodes for ethanol detection in sweat. Analytical and Bioanalytical Chemistry. 2024;416(24):5303-5316. doi:10.1007/s00216-024-05467-7

BibTeX
@article{Marchian2024,
  author = {Marchianò, Verdiana and Tricase, Angelo and Macchia, Eleonora and Bollella, Paolo and Torsi, Luisa},
  title = {Self-powered wearable biosensor based on stencil-printed carbon nanotube electrodes for ethanol detection in sweat},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  volume = {416},
  number = {24},
  pages = {5303--5316},
  doi = {10.1007/s00216-024-05467-7}
}
Kostenlos starten →