EUVIMEDEUVIMED entdecken
Crossref

Iridium(III) solvent complex–based electrogenerated chemiluminescence method for the detection of 3-methylhistidine in urine

Yu Liu, Yue Li, Manping Qian, Yang Wu, Meng Li, Chengxiao Zhang, Honglan Qi

Analytical and Bioanalytical Chemistry · 2024

DOI: 10.1007/s00216-024-05402-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Yu Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University,…. Hauptthemen laut MEDLINE: Iridium, Luminescent Measurements, Methylhistidines, Limit of Detection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Natural Science Basic Research Program of Shaanxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

3-Methylhistidine (3-MeHis) is increasingly used as an indicator of muscle protein breakdown. The development of a sensitive, simple, and non-invasive method for 3-MeHis assay is important in clinical practice. Herein, a sensitive, simple, and non-invasive electrogenerated chemiluminescence (ECL) method was proposed for the quantitation of 3-MeHis in urine by using an iridium(III) solvent complex ([Ir(dfppy)2(DMSO)Cl], dfppy = 2-(2,4-difluorophenyl)pyridine, Ir-DMSO) as a signal reagent. The photoluminescence (PL) and ECL responses of Ir-DMSO to 3-MeHis were studied. The ECL intensity of Ir-DMSO was enhanced in the presence of 3-MeHis because of the coordination recognition between Ir-DMSO and the imidazole group of 3-MeHis. Based on the enhancement of ECL intensity, 3-MeHis can be sensitively detected in the range of 5 to 25 μM. The detection limit was 0.4 μM. This is the first report of an ECL method for the quantitation of 3-MeHis. Further, to investigate the feasibility of the Ir-DMSO-based ECL method in practical applications, the developed ECL method was applied for 3-MeHis assay in urine samples of 28 healthy volunteers and 2 patients. The urine samples from patients hospitalized with obesity and kidney disease and healthy individuals were distinguished by the ECL responses of Ir-DMSO. The proposed ECL method based on the coordination recognition between iridium(III) solvent complex and the imidazole group of 3-MeHis allows inexpensive, fast, non-invasive, and sensitive detection of 3-MeHis in urine, which is promising for assessing large volumes of patients for routine analysis in clinical practices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IridiumLuminescent MeasurementsMethylhistidinesLimit of DetectionSolventsHumansCoordination ComplexesMaleElectrochemical Techniques

Stichwörter der Autor:innen

3-MethylhistidineCoordinationElectrogenerated chemiluminescenceIridium(III) solvent complexUrine sample

Substanzen

IridiumMethylhistidinesSolvents3-methylhistidineCoordination Complexes

Autor:innen und Institutionen

  • Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China. honglanqi@snnu.edu.cn.

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China
  • Natural Science Basic Research Program of Shaanxi Province

Zitieren

APA

Liu, Y., Li, Y., Qian, M., Wu, Y., Li, M., Zhang, C., & Qi, H. (2024). Iridium(III) solvent complex–based electrogenerated chemiluminescence method for the detection of 3-methylhistidine in urine. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05402-w

Vancouver

Liu Y, Li Y, Qian M, Wu Y, Li M, Zhang C, et al. Iridium(III) solvent complex–based electrogenerated chemiluminescence method for the detection of 3-methylhistidine in urine. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05402-w

BibTeX
@article{Liu2024,
  author = {Liu, Yu and Li, Yue and Qian, Manping and Wu, Yang and Li, Meng and Zhang, Chengxiao and Qi, Honglan},
  title = {Iridium(III) solvent complex–based electrogenerated chemiluminescence method for the detection of 3-methylhistidine in urine},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  doi = {10.1007/s00216-024-05402-w}
}
Kostenlos starten →