EUVIMEDEUVIMED entdecken
Validierungsstudie

Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application

Maozhu Liu, Fei Fan, Jing Zhang, Shiyong Fang, Yangjuan Bai, Yamei Li, Yuangao Zou, Yunfei An, Xinhua Dai

Analytical and Bioanalytical Chemistry · 2024-05 · 416 (12) · 3073-3083

DOI: 10.1007/s00216-024-05257-1 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 22.03.2024. Verfasst von Maozhu Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Glycine, Glyphosate, Aminobutyrates. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: The Key Research and Development Project of the Department of Science and Technology of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diquat (DQ), paraquat (PQ), glufosinate (GLU), and glyphosate (GLYP) are commonly used herbicides that have been confirmed to be toxic to humans. Rapid and accurate measurements of these toxicants in clinical practice are beneficial for the correct diagnosis and timely treatment of herbicide-poisoned patients. The present study aimed to establish an efficient, convenient, and reliable method to achieve the simultaneous quantification of DQ, PQ, GLU, and GLYP in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS) without using derivatization or ion-pairing reagents. DQ, PQ, GLU, and GLYP were extracted by the rapid protein precipitation and liquid-liquid extraction method and then separated and detected by LC-MS/MS. Subsequently, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, extraction recovery, matrix effect, dilution integrity, and stability were evaluated to validate the method based on the FDA criteria. Finally, the validated method was applied to real plasma samples collected from 166 Chinese patients with herbicide poisoning. The results showed satisfactory linearity with low LOD (1 ng/mL for DQ and PQ, 5 ng/mL for GLU, and 10 ng/mL for GLYP, respectively) and low LOQ (5 ng/mL for DQ and PQ, 25 ng/mL for GLU and GLYP, respectively). In addition, the precision, accuracy, extraction recovery, and stability of the method were acceptable. The matrix effect was not observed in the analyzed samples. Moreover, the developed method was successfully applied to determine the target compounds in real plasma samples. These data provided reliable evidence for the application of this LC-MS/MS method for clinical poisoning detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryGlycineGlyphosateAminobutyratesDiquatParaquatHerbicidesLimit of DetectionHumansChromatography, LiquidReproducibility of Results

Stichwörter der Autor:innen

DiquatGlufosinateGlyphosateHuman plasmaLC-MS/MSParaquat

Substanzen

GlycinephosphinothricinGlyphosateAminobutyratesDiquatParaquatHerbicides

Autor:innen und Institutionen

  • Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Department of Pharmacy, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • West China School of Basic Medical Science & Forensic Medicine, Sichuan University, Chengdu, 610041, Sichuan, China.
  • West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • School of Forensic Medicine, Wannan Medical College, Wuhu, 241002, Anhui, China.
  • Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China. daixinhua@scu.edu.cn.

Förderung

  • The Key Research and Development Project of the Department of Science and Technology of Sichuan Province

Zitieren

APA

Liu, M., Fan, F., Zhang, J., Fang, S., Bai, Y., Li, Y., Zou, Y., An, Y., & Dai, X. (2024). Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application. Analytical and Bioanalytical Chemistry, 416(12), 3073-3083. https://doi.org/10.1007/s00216-024-05257-1

Vancouver

Liu M, Fan F, Zhang J, Fang S, Bai Y, Li Y, et al. Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application. Analytical and Bioanalytical Chemistry. 2024;416(12):3073-3083. doi:10.1007/s00216-024-05257-1

BibTeX
@article{Liu2024,
  author = {Liu, Maozhu and Fan, Fei and Zhang, Jing and Fang, Shiyong and Bai, Yangjuan and Li, Yamei and Zou, Yuangao and An, Yunfei and Dai, Xinhua},
  title = {Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  volume = {416},
  number = {12},
  pages = {3073--3083},
  doi = {10.1007/s00216-024-05257-1}
}
Kostenlos starten →