A High‑Throughput, Non‐Derivatization Method for Determination of Glyphosate, Glufosinate, and Their Metabolites in Water and Sediments Using Pass‐Through Cleanup and UHPLC–MS/MS
Journal of Separation Science · 2026-11 · 49 (11)
DOI: 10.1002/jssc.70567 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Separation Science, online erschienen am 03.11.2026. Verfasst von Xiao Yang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Fisheries Research Institute and Aquatic Products Seed Stock Station, Changsha, P. R. China. Hauptthemen laut MEDLINE: Aminobutyrates, Glycine, Water Pollutants, Chemical, Herbicides. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Hunan Provincial Natural Science Foundation of China, the earmarked fund for China Agriculture Research System.
Abstract (Originalsprache)
Glyphosate (GLYP) and glufosinate (GLUF) are widely used herbicides that can persist in aquatic environments. Rapid, sensitive, and matrix‐versatile analytical methods for the simultaneous monitoring of these herbicides, along with their major metabolites (aminomethylphosphonic acid: AMPA, and 3‐(methyl‐phosphinico)‐propionic acid: MPPA), remain limited. Most existing liquid chromatography‐tandem mass spectrometry (LC–MS/MS) methods require derivatization or target only food matrices, with little attention to environmental water and sediment. In this study, we developed a high‐throughput, non‐derivatization ultra‐high‐performance LC (UHPLC)–MS/MS method incorporating solid‐phase extraction using Oasis PRiME HLB cartridges to directly determine all four analytes in both water and sediment samples. The PRiME HLB cartridge effectively reduces interfering substances (such as salts, organic matter, and phospholipids) without conditioning or elution steps, thereby simplifying sample preparation and enabling high‐throughput analysis. The method was validated across six distinct environmental matrices (pond, lake, river water, and corresponding sediments). Excellent linearity ( R 2 > 0.996), satisfactory recoveries (78.3%–104.7%), precision (RSD < 15%), and sensitivity (limits of detection [LODs]: 0.3–0.5 µg L − 1 for water and 2–3 µg kg − 1 for sediment) were achieved, with negligible matrix effects (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hunan Fisheries Research Institute and Aquatic Products Seed Stock Station, Changsha, P. R. China.
- Fishery Products Quality Testing Center, Ministry of Agriculture and Rural Affairs, Changsha, P. R. China.
- SCIEX Analytical Instrument Trading Co., Ltd, Shanghai, P. R. China.
Förderung
- Hunan Provincial Natural Science Foundation of China
- the earmarked fund for China Agriculture Research System
Zitieren
APA
Yang, X., Lei, Q., Suo, W., Zeng, C., Liu, L., Ke, F., He, Y., Chen, X., Wan, Y., & Li, X. (2026). A High‑Throughput, Non‐Derivatization Method for Determination of Glyphosate, Glufosinate, and Their Metabolites in Water and Sediments Using Pass‐Through Cleanup and UHPLC–MS/MS. Journal of Separation Science, 49(11). https://doi.org/10.1002/jssc.70567
Vancouver
Yang X, Lei Q, Suo W, Zeng C, Liu L, Ke F, et al. A High‑Throughput, Non‐Derivatization Method for Determination of Glyphosate, Glufosinate, and Their Metabolites in Water and Sediments Using Pass‐Through Cleanup and UHPLC–MS/MS. Journal of Separation Science. 2026;49(11). doi:10.1002/jssc.70567
BibTeX
@article{Yang2026,
author = {Yang, Xiao and Lei, Qin and Suo, Wenwen and Zeng, Chunfang and Liu, Lingli and Ke, Fan and He, Yong and Chen, Xiangyi and Wan, Yiwen and Li, Xiaoling},
title = {A High‑Throughput, Non‐Derivatization Method for Determination of Glyphosate, Glufosinate, and Their Metabolites in Water and Sediments Using Pass‐Through Cleanup and UHPLC–MS/MS},
journal = {Journal of Separation Science},
year = {2026},
volume = {49},
number = {11},
doi = {10.1002/jssc.70567}
}
EUVIMED