Improved sensitivity and automation of a multi-step upconversion lateral flow immunoassay using a 3D-printed actuation mechanism
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-024-05156-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Kirsti Raiko und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biotechnology Unit, Department of Life Technologies, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520, Turku, Finland. kisrai@ut…. Hauptthemen laut MEDLINE: Nanoparticles. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Business Finland, University of Turku.
Abstract (Originalsprache)
The development of sensitive point-of-care (POC) assay platforms is of interest for reducing the cost and time of diagnostics. Lateral flow assays (LFAs) are the gold standard for POC systems, but their sensitivity as such is inadequate, for example, in the case of cardiac diagnostics. The performance can be improved by incorporating different steps, such as pre-incubation to prolong the interaction time between sample and reporter for immunocomplex formation, and washing steps for background reduction. However, for POC assays, manual steps by the assay conductor are not desired. In this research, upconverting nanoparticles (UCNPs) were coated with poly(acrylic acid) (PAA) and conjugated to anti-cTnI antibodies, yielding non-clustering particles with low non-specific binding. The performance of cTnI-LFA in the PAA-anti-cTnI-UCNPs was compared to the same UCNPs with a commercial carboxyl surface. A kitchen-timer mechanism was embedded in a 3D-printed housing to produce a low-cost actuator facilitating a timed pre-incubation step for reporter and sample, and a washing step, to enable a multi-step cTnI-LFA with minimized manual labour. PAA-UCNPs showed improved mobility on nitrocellulose compared to those with a commercial surface. The mechanical actuator system was shown to improve sensitivity compared to a labour-intensive multi-step dipstick method, despite pre-incubation occurring during shaking and heating in the dipstick method. The limit of detection decreased from 7.6 to 1.5 ng/L cTnI in human plasma. The presented actuator can be easily modified for sensitivity improvement in the LFA for different analytes via pre-incubation and washing steps. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biotechnology Unit, Department of Life Technologies, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520, Turku, Finland. kisrai@utu.fi.
- Biotechnology Unit, Department of Life Technologies, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520, Turku, Finland.
Förderung
- Business Finland
- University of Turku
Zitieren
APA
Raiko, K., Nääjärvi, O., Ekman, M., Koskela, S., Soukka, T., Martiskainen, I., & Salminen, T. (2024). Improved sensitivity and automation of a multi-step upconversion lateral flow immunoassay using a 3D-printed actuation mechanism. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05156-5
Vancouver
Raiko K, Nääjärvi O, Ekman M, Koskela S, Soukka T, Martiskainen I, et al. Improved sensitivity and automation of a multi-step upconversion lateral flow immunoassay using a 3D-printed actuation mechanism. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05156-5
BibTeX
@article{Raiko2024,
author = {Raiko, Kirsti and Nääjärvi, Oskari and Ekman, Miikka and Koskela, Sonja and Soukka, Tero and Martiskainen, Iida and Salminen, Teppo},
title = {Improved sensitivity and automation of a multi-step upconversion lateral flow immunoassay using a 3D-printed actuation mechanism},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05156-5}
}
EUVIMED