EUVIMEDEUVIMED entdecken
Crossref

Molecularly imprinted sensor based on poly-o-phenylenediamine-hydroquinone polymer for β-amyloid-42 detection

Minling Ding, Huizhe Niu, Ping Guan, Xiaoling Hu

Analytical and Bioanalytical Chemistry · 2023

DOI: 10.1007/s00216-023-04552-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2023. Verfasst von Minling Ding und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China. Hauptthemen laut MEDLINE: Polymers, Molecular Imprinting. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: Shaanxi province key R&D program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A sensitive and selective molecularly imprinted polymer (MIP) sensor was developed for the determination of amyloid-β (1-42) (Aβ42). The glassy carbon electrode (GCE) was successively modified with electrochemical reduction graphene oxide (ERG) and poly(thionine-methylene blue) (PTH-MB). The MIPs were synthesized by electropolymerization with Aβ42 as a template and o-phenylenediamine (o-PD) and hydroquinone (HQ) as functional monomers. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CC), and differential pulse voltammetry (DPV) were used to study the preparation process of the MIP sensor. The preparation conditions of the sensor were investigated in detail. In optimal experimental conditions, the response current of the sensor was linear in the range of 0.12-10 μg mL-1 with a detection limit of 0.018 ng mL-1. The MIP-based sensor successfully detected Aβ42 in commercial fetal bovine serum (cFBS) and artificial cerebrospinal fluid (aCSF).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolymersMolecular ImprintingHydroquinonesElectrochemical TechniquesMolecularly Imprinted PolymersElectrodesLimit of DetectionPhenylenediamines

Stichwörter der Autor:innen

Amyloid-β (1–42)Differential pulse voltammetryElectrochemically reduced graphene oxideMolecularly imprinted sensorPoly(thionine-methylene blue)

Substanzen

PolymersHydroquinonesMolecularly Imprinted Polymerspoly(o-phenylenediamine)Phenylenediamineshydroquinone

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China.
  • School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China. guanping1113@nwpu.edu.cn.
  • School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China. huxl@nwpu.edu.cn.

Förderung

  • Shaanxi province key R&D program

Zitieren

APA

Ding, M., Niu, H., Guan, P., & Hu, X. (2023). Molecularly imprinted sensor based on poly-o-phenylenediamine-hydroquinone polymer for β-amyloid-42 detection. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-023-04552-7

Vancouver

Ding M, Niu H, Guan P, Hu X. Molecularly imprinted sensor based on poly-o-phenylenediamine-hydroquinone polymer for β-amyloid-42 detection. Analytical and Bioanalytical Chemistry. 2023. doi:10.1007/s00216-023-04552-7

BibTeX
@article{Ding2023,
  author = {Ding, Minling and Niu, Huizhe and Guan, Ping and Hu, Xiaoling},
  title = {Molecularly imprinted sensor based on poly-o-phenylenediamine-hydroquinone polymer for β-amyloid-42 detection},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2023},
  doi = {10.1007/s00216-023-04552-7}
}
Kostenlos starten →