Simulated low-dose multi-detector computed tomography: spatial effects on surrogate parameters of bone strength at the proximal femur

Nico Sollmann, Kai Mei, Maximilian T Löffler, Sebastian Rühling, Meinrad Beer, Claus Zimmer, Jan S Kirschke, Peter B Noël, Thomas Baum, Julio Carballido-Gamio

Osteoporosis International · 2025

DOI: 10.1007/s00198-025-07467-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Osteoporosis International, 2025. Verfasst von Nico Sollmann und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany. nico.sollmann@tum.de. Hauptthemen laut MEDLINE: Bone Density, Multidetector Computed Tomography, Femur Head, Femur. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIAMS NIH HHS, National Institute of Health, B. Braun-Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated simulated tube current reduction and sparse sampling for low-dose computed tomography (CT) regarding volumetric bone mineral density (vBMD) and cortical bone thickness (Ct.Th) of the proximal femur. Sparse sampling with dose reductions of up to 90% may still allow extraction of bone strength parameters with clinically acceptable accuracy. INTRODUCTION: We aimed to investigate effects of CT with simulated lowered tube current and sparse sampling on trabecular and cortical vBMD as well as Ct.Th of the entire proximal femur, its subregions, and with detailed spatial assessments. METHODS: Clinical routine multi-detector CT (MDCT) scans covering the hips from 40 patients were used for simulations of low-dose imaging with 50% and 10% of the original tube current (D50, D10) or projections (P50, P10) combined with statistical iterative reconstruction (SIR), which were then compared against original data with full dose (D100 P100) regarding trabecular vBMD, cortical vBMD, and Ct.Th. An automated framework for multi-parametric assessments was used. Relative errors by comparing measures from original data and simulated low-dose data, regression analyses, Bland-Altman analyses, and statistical parametric mapping (SPM, to assess the spatial distribution of accuracy) were computed. RESULTS: Sparse sampling enabled drastic reductions of radiation exposure (down to 10% of original imaging) while still producing determinants of bone strength with clinically acceptable relative changes. Lower biases according to Bland-Altman analyses were observed for sparse sampling compared to imaging with virtually lowered tube currents (D10 P100 versus D100 P10) regarding trabecular vBMD, cortical vBMD, as well as Ct.Th. Better accuracy across the whole proximal femur for D100 P50 than for D50 P100 and for D100 P10 than for D10 P100 was observed. CONCLUSIONS: Sparse sampling with SIR may enable drastic reductions of radiation exposure (up to 90% of original doses) for opportunistically measuring image-based surrogate parameters of bone strength.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone DensityMultidetector Computed TomographyFemur HeadFemurHumansRadiation DosageFemaleAgedMaleMiddle AgedCortical BoneCancellous BoneRadiographic Image Interpretation, Computer-AssistedComputer SimulationAged, 80 and overAdult

Stichwörter der Autor:innen

BiomechanicsBone QCT/microCTFracture risk assessmentOsteoporosisRadiologyScreening

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany. nico.sollmann@tum.de.
  • Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany. nico.sollmann@tum.de.
  • TUM-Neuroimaging Center, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany. nico.sollmann@tum.de.
  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
  • Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.

Förderung

  • NIAMS NIH HHS
  • National Institute of Health
  • B. Braun-Stiftung
  • Deutsche Forschungsgemeinschaft
  • Joachim Herz Stiftung
  • Universitätsklinikum Ulm

Zitieren

APA

Sollmann, N., Mei, K., Löffler, M. T., Rühling, S., Beer, M., Zimmer, C., Kirschke, J. S., Noël, P. B., Baum, T., & Carballido-Gamio, J. (2025). Simulated low-dose multi-detector computed tomography: spatial effects on surrogate parameters of bone strength at the proximal femur. Osteoporosis International. https://doi.org/10.1007/s00198-025-07467-4

Vancouver

Sollmann N, Mei K, Löffler MT, Rühling S, Beer M, Zimmer C, et al. Simulated low-dose multi-detector computed tomography: spatial effects on surrogate parameters of bone strength at the proximal femur. Osteoporosis International. 2025. doi:10.1007/s00198-025-07467-4

BibTeX
@article{Sollmann2025,
  author = {Sollmann, Nico and Mei, Kai and Löffler, Maximilian T and Rühling, Sebastian and Beer, Meinrad and Zimmer, Claus and Kirschke, Jan S and Noël, Peter B and Baum, Thomas and Carballido-Gamio, Julio},
  title = {Simulated low-dose multi-detector computed tomography: spatial effects on surrogate parameters of bone strength at the proximal femur},
  journal = {Osteoporosis International},
  year = {2025},
  doi = {10.1007/s00198-025-07467-4}
}
Kostenlos starten →