A Reliable and Straightforward Combination of vortex-assisted Dispersive Magnetic solid-phase Extraction with Direct Sorbent Sampling for Highly Sensitive Silver Determination in Water Samples Using Flame and Metal Furnace AAS
Bulletin of Environmental Contamination and Toxicology · 2024
DOI: 10.1007/s00128-024-03955-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bulletin of Environmental Contamination and Toxicology, 2024. Verfasst von Diego Prudencio Dos Santos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil. Hauptthemen laut MEDLINE: Solid Phase Extraction, Silver, Water Pollutants, Chemical, Spectrophotometry, Atomic. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico.
Abstract (Originalsprache)
In the present paper, the assessment of vortex-assisted dispersive magnetic solid-phase extraction using amino-functionalized mesoporous combined with direct magnetic sorbent sampling (DMSS) in flame or furnace atomic absorption spectrometry (FAAS or FF-AAS) was demonstrated for highly sensitive silver determination in water samples. The developed method showed significant enrichment factors compared to conventional pneumatic nebulization by FAAS, 607 for DMSS-FF-AAS and 114 for DMSS-FAAS. The analytical curve showed linearity in the range from 5.0 to 70.0 µg L- 1 and 1.0 to 15.0 µg L- 1 and limits of detection of 0.59 and 0.09 µg L- 1 for DMSS-FAAS and DMSS-FF-AAS, respectively. The intra and inter-day precision evaluated as a percentage of the relative standard deviation (RSD,%) ranged from 1.89 to 4.71% for levels of 25.0 and 65.0 µg L- 1. The method was applied in different kinds of water samples without matrix effects, yielding recovery values from 90 to 110%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil.
- Federal Institute of Parana (IFPR), Campus Irati, Irati, PR, 84507-302, Brazil.
- Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil.
- Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil. ctarleyquim@yahoo.com.br.
- National Institute of Science and Technology in Bioanalysis, Department of Analytical Chemistry, State University of Campinas, Campinas, SP, 13083-970, Brazil. ctarleyquim@yahoo.com.br.
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
Zitieren
APA
Santos, D. P. D., Ferreira, M. D. P., Diniz, K. M., Segatelli, M. G., Figueiredo, E. C., & Tarley, C. R. T. (2024). A Reliable and Straightforward Combination of vortex-assisted Dispersive Magnetic solid-phase Extraction with Direct Sorbent Sampling for Highly Sensitive Silver Determination in Water Samples Using Flame and Metal Furnace AAS. Bulletin of Environmental Contamination and Toxicology. https://doi.org/10.1007/s00128-024-03955-1
Vancouver
Santos DPD, Ferreira MDP, Diniz KM, Segatelli MG, Figueiredo EC, Tarley CRT. A Reliable and Straightforward Combination of vortex-assisted Dispersive Magnetic solid-phase Extraction with Direct Sorbent Sampling for Highly Sensitive Silver Determination in Water Samples Using Flame and Metal Furnace AAS. Bulletin of Environmental Contamination and Toxicology. 2024. doi:10.1007/s00128-024-03955-1
BibTeX
@article{Santos2024,
author = {Santos, Diego Prudencio Dos and Ferreira, Milena do Prado and Diniz, Kristiany Moreira and Segatelli, Mariana Gava and Figueiredo, Eduardo Costa de and Tarley, César Ricardo Teixeira},
title = {A Reliable and Straightforward Combination of vortex-assisted Dispersive Magnetic solid-phase Extraction with Direct Sorbent Sampling for Highly Sensitive Silver Determination in Water Samples Using Flame and Metal Furnace AAS},
journal = {Bulletin of Environmental Contamination and Toxicology},
year = {2024},
doi = {10.1007/s00128-024-03955-1}
}
EUVIMED