EUVIMEDEUVIMED entdecken
Crossref

Rapid green analytical methodology for simultaneous monitoring of nitrosamines and semi-volatile organic compounds in water and human urine samples

Shih-Tao Hu, Uday Shashikumar, Swapnil Gurrani, Yu-Tung Tseng, Karthikeyan Prakasham, Cheng-Te Huang, Anbarasu Krishnan, Chao-En Wang, Po-Chin Huang, Vinoth Kumar Ponnusamy

Environmental Geochemistry and Health · 2024

DOI: 10.1007/s10653-024-02207-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Geochemistry and Health, 2024. Verfasst von Shih-Tao Hu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan. Hauptthemen laut MEDLINE: Nitrosamines, Volatile Organic Compounds, Water Pollutants, Chemical. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nitrosamines and semi-volatile organic compounds (SVOCs) are carcinogenic contaminants in water and biological matrices. Conventional analytical methods often struggle to detect trace concentrations due to poor extraction efficacies. This study presents a novel, low-cost, in-syringe-assisted fast extraction cum cleanup technique coupled with GC-FID for monitoring four nitrosamines and two SVOCs in drinking water and human urine samples to measure the contamination and exposure levels. This extraction protocol combines a novel green in-syringe liquid-liquid extraction step using dimethyl carbonate as the green extraction solvent, coupled with a semi-automated solid-phase extraction cleanup process. Then, the final extractant is analyzed using gas chromatography-flame ionization detection (GC-FID) for monitoring. The method demonstrated excellent linearity (R2 > 0.998) between 1.5 and 500 ng mL⁻1 for all six target compounds. Detection limits ranged from 1.0 to 2.0 ng mL⁻1. Extraction recoveries were between 87 and 105% for both urine samples and water samples. Intra-day and inter-day precision were below 9% RSD. The blue applicability grade index evaluation scored 70.0, indicating good practical applicability. The developed analytical protocol offers a sensitive, accurate, low-cost, rapid, and environmentally friendly method for simultaneously quantifying multiple nitrosamines and SVOCs in environmental and human samples. Its performance characteristics and sustainability metrics suggest the potential for broad application in monitoring and exposure studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NitrosaminesVolatile Organic CompoundsWater Pollutants, ChemicalHumansChromatography, GasGreen Chemistry TechnologySolid Phase ExtractionDrinking WaterLimit of DetectionEnvironmental MonitoringLiquid-Liquid Extraction

Stichwörter der Autor:innen

GC-FIDHuman Urine analysisIn-syringe based green fast extraction techniqueNitrosaminesSemi-volatile organic compoundsWater analysis

Substanzen

NitrosaminesVolatile Organic CompoundsWater Pollutants, ChemicalDrinking Water

Autor:innen und Institutionen

  • Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan.
  • Department of Applied Science and Humanities, Invertis University, Bareilly, Uttar Pradesh, India.
  • Research Center for Precision Environmental Medicine, College of Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan.
  • PhD Program in Environmental and Occupational Medicine, College of Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan.
  • Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, 602105, India.
  • Research and Development Division, Great Engineering Technology (GETECH) Corporation, No.392, Yucheng Rd., Zuoying District, Kaohsiung City, 813, Taiwan.

Förderung

  • National Science and Technology Council

Zitieren

APA

Hu, S. T., Shashikumar, U., Gurrani, S., Tseng, Y. T., Prakasham, K., Huang, C. T., Krishnan, A., Wang, C. E., Huang, P. C., & Ponnusamy, V. K. (2024). Rapid green analytical methodology for simultaneous monitoring of nitrosamines and semi-volatile organic compounds in water and human urine samples. Environmental Geochemistry and Health. https://doi.org/10.1007/s10653-024-02207-9

Vancouver

Hu ST, Shashikumar U, Gurrani S, Tseng YT, Prakasham K, Huang CT, et al. Rapid green analytical methodology for simultaneous monitoring of nitrosamines and semi-volatile organic compounds in water and human urine samples. Environmental Geochemistry and Health. 2024. doi:10.1007/s10653-024-02207-9

BibTeX
@article{Hu2024,
  author = {Hu, Shih-Tao and Shashikumar, Uday and Gurrani, Swapnil and Tseng, Yu-Tung and Prakasham, Karthikeyan and Huang, Cheng-Te and Krishnan, Anbarasu and Wang, Chao-En and Huang, Po-Chin and Ponnusamy, Vinoth Kumar},
  title = {Rapid green analytical methodology for simultaneous monitoring of nitrosamines and semi-volatile organic compounds in water and human urine samples},
  journal = {Environmental Geochemistry and Health},
  year = {2024},
  doi = {10.1007/s10653-024-02207-9}
}
Kostenlos starten →