Recommendations for selection of target parameters and process recommendations for audiological and technical functional testing of cochlear implant
HNO · 2025
DOI: 10.1007/s00106-025-01629-w ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift HNO, 2025. Verfasst von A Müller und 13 weiteren Autor:innen. Beteiligte Einrichtung: Hearing Center Berlin (HZB), ORL Department, Head, Neck, Plastic and Cosmetic Surgery, Center for Hearing Implants, Vivantes Klinikum im Friedrichsha…. Hauptthemen laut MEDLINE: Cochlear Implants, Audiometry, Evoked Response, Cochlear Implantation, Audiology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Continuous monitoring of the technical and physiological function of cochlear implants (CI) is a central part of the care process. Despite worldwide efforts to standardise procedures, there is still considerable variation between CI centres, particularly in terms of the methods used, their practical implementation and the definition of meaningful target parameters. A standardised structured test procedure is needed for reliable quality assurance and better comparability. Against this background, the ADANO Working Group for Evoked Response Audiometry (AG-ERA), in close cooperation with the Cochlear Implants and Implantable Hearing Systems Committee of the German Society of Audiology (DGA), developed a minimum standard for audiological and technical functional testing of CIs in an open consensus process. This standard defines basic requirements for performance and documentation and serves as a practical recommendation for CI centres. It is intended to improve interdisciplinary cooperation, increase the quality of care and enable structured long-term optimised care for CI patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hearing Center Berlin (HZB), ORL Department, Head, Neck, Plastic and Cosmetic Surgery, Center for Hearing Implants, Vivantes Klinikum im Friedrichshain, Landsberger Allee 49, 10249, Berlin, Germany. alexander.mueller@vi…
- Clinic and Polyclinic for Ear, Nose and Throat Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Department of ENT, Head & Neck Surgery, University Medicine Greifswald, Greifswald, Germany.
- Department of Otolaryngology, Head and Neck Surgery, University Medical Center Bonn, Bonn, Germany.
- Ear, Nose and Throat Clinic, Head and Neck Surgery, University Hospital Erlangen, Erlangen, Germany.
- Department of Otorhinolaryngology, LMU Klinikum, Munich, Germany.
Zitieren
APA
Müller, A., Blümer, M., Dziemba, O. C., Elsholz, A., Fröhlich, L., Hoppe, U., Polterauer, D., Rahne, T., Steffens, T., Walger, M., Weißgerber, T., Wesarg, T., Zirn, S., & Rader, T. (2025). Recommendations for selection of target parameters and process recommendations for audiological and technical functional testing of cochlear implant. HNO. https://doi.org/10.1007/s00106-025-01629-w
Vancouver
Müller A, Blümer M, Dziemba OC, Elsholz A, Fröhlich L, Hoppe U, et al. Recommendations for selection of target parameters and process recommendations for audiological and technical functional testing of cochlear implant. HNO. 2025. doi:10.1007/s00106-025-01629-w
BibTeX
@article{Mller2025,
author = {Müller, A and Blümer, M and Dziemba, O C and Elsholz, A and Fröhlich, L and Hoppe, U and Polterauer, D and Rahne, T and Steffens, T and Walger, M and Weißgerber, T and Wesarg, T and Zirn, S and Rader, T},
title = {Recommendations for selection of target parameters and process recommendations for audiological and technical functional testing of cochlear implant},
journal = {HNO},
year = {2025},
doi = {10.1007/s00106-025-01629-w}
}
EUVIMED