EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of the design of 3D-printed indirect bonding trays and experience of the clinician on the accuracy of bracket placement

Hisham Sabbagh, Lea Hoffmann, Andrea Wichelhaus, Andreas Kessler

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · 2025

DOI: 10.1007/s00056-024-00517-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2025. Verfasst von Hisham Sabbagh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany. hisham.sabbagh@…. Hauptthemen laut MEDLINE: Orthodontic Brackets, Printing, Three-Dimensional, Dental Bonding, Clinical Competence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim was to investigate the influence of three different three-dimensional (3D)-printed bonding tray designs and professional experience on accuracy of indirect bracket placement.

Methods

Virtual bracket placement was performed on a scanned dental model using OnyxCeph software (Image Instruments, Chemnitz, Germany). Three different designs for indirect bonding trays (open, semi-open, and closed design) were created and produced using a 3D printer. To analyze the influence of professional experience, one of the three tray designs was produced twice. In this case, bracket placement was performed by an inexperienced dentist. Bracket positions were scanned after the indirect bonding procedure. Linear and angular transfer errors were measured. Significant differences between the target and actual situation were analyzed using the Kruskal–Wallis and χ 2 test.

Results

All bonding tray designs resulted in comparable results. The results of the unexperienced dentist showed significantly higher deviations than those for the experienced orthodontist in the torque direction. However, the mean values were comparable. The open tray design exceeded the clinically acceptable limits of 0.25 mm and 1° more often. The inexperienced dentist exceeded these limits significantly more often than the experienced orthodontist in the vertical and torque direction. The immediate bracket loss rate showed no significant differences between the different tray designs. Significantly more bracket losses were observed for the inexperienced dentist during the procedure compared to the experienced orthodontist.

Conclusions

The bonding tray design and professional experience had an influence on the exceedance of clinically relevant limits of positioning accuracy and on the bracket loss rate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic BracketsPrinting, Three-DimensionalDental BondingClinical CompetenceHumansReproducibility of ResultsModels, DentalEquipment Design

Stichwörter der Autor:innen

3D printingBracket placement accuracyLearning curveOrthodontic bracketsTray design

Autor:innen und Institutionen

  • Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany. hisham.sabbagh@med.uni-muenchen.de.
  • Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
  • Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany.

Zitieren

APA

Sabbagh, H., Hoffmann, L., Wichelhaus, A., & Kessler, A. (2025). Influence of the design of 3D-printed indirect bonding trays and experience of the clinician on the accuracy of bracket placement. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie. https://doi.org/10.1007/s00056-024-00517-2

Vancouver

Sabbagh H, Hoffmann L, Wichelhaus A, Kessler A. Influence of the design of 3D-printed indirect bonding trays and experience of the clinician on the accuracy of bracket placement. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie. 2025. doi:10.1007/s00056-024-00517-2

BibTeX
@article{Sabbagh2025,
  author = {Sabbagh, Hisham and Hoffmann, Lea and Wichelhaus, Andrea and Kessler, Andreas},
  title = {Influence of the design of 3D-printed indirect bonding trays and experience of the clinician on the accuracy of bracket placement},
  journal = {Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie},
  year = {2025},
  doi = {10.1007/s00056-024-00517-2}
}
Kostenlos starten →