EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Evaluating the accuracy of one-piece and three-piece 3D-printed indirect bonding transfer trays: An in vitro study

Michał Wajda, Joanna Lis, Beata Kawala

Dental and Medical Problems · 2024

DOI: 10.17219/dmp/184145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dental and Medical Problems, 2024. Verfasst von Michał Wajda und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Integrated Dentistry, Wroclaw Medical University, Poland. Hauptthemen laut MEDLINE: Printing, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Recent developments in computer-aided design/computer-aided manufacturing (CAD/CAM) and 3D printing have enabled the fabrication of digital indirect bonding (IDB) transfer trays. These modern products require thorough investigation. OBJECTIVES: The aim of the study was to determine the accuracy of one-piece and three-piece IDB transfer trays in vitro. MATERIAL AND METHODS: An initial dental scan (IDS) of a randomly selected patient with digitally positioned brackets served as the master scan (MS) for designing 16 IDB transfer trays of each type. They were 3D printed and used for bonding 448 brackets to the models. Subsequently, the models were scanned with a TRIOS® 3 Intraoral Scanner (3Shape A/S, Copenhagen, Denmark), producing actual scans (ASs). The accuracy of bracket positioning was measured digitally on both MSs and ASs. The measurements were compared to the Objective Grading System for dental casts provided by the American Board of Orthodontics (ABO). RESULTS: The 2 types of IDB transfer trays showed comparable accuracy. All linear errors were within the clinically acceptable range, whereas the angular measurements demonstrated significant variability, resulting in clinically unacceptable transfer errors that ranged from 3.3% to 90.3%. CONCLUSIONS: The study results cannot be unconditionally extrapolated to other types of IDB transfer trays due to the diversity of their properties and features. The study evaluated the in vitro accuracy of IDB transfer trays. The revealed number of errors may be even higher in vivo due to limitations in visibility, salivary flow, interference from the tongue, and difficulties in achieving a proper fit of the IDB transfer tray to the teeth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalHumansIn Vitro TechniquesModels, DentalDental BondingOrthodontic BracketsComputer-Aided Design

Stichwörter der Autor:innen

3D printingIBT resincomputer-aided designorthodontic bracketsorthodontics

Autor:innen und Institutionen

  • Department of Integrated Dentistry, Wroclaw Medical University, Poland.
  • Department of Maxillofacial Orthopedics and Orthodontics, Wroclaw Medical University, Poland.

Zitieren

APA

Wajda, M., Lis, J., & Kawala, B. (2024). Evaluating the accuracy of one-piece and three-piece 3D-printed indirect bonding transfer trays: An in vitro study. Dental and Medical Problems. https://doi.org/10.17219/dmp/184145

Vancouver

Wajda M, Lis J, Kawala B. Evaluating the accuracy of one-piece and three-piece 3D-printed indirect bonding transfer trays: An in vitro study. Dental and Medical Problems. 2024. doi:10.17219/dmp/184145

BibTeX
@article{Wajda2024,
  author = {Wajda, Michał and Lis, Joanna and Kawala, Beata},
  title = {Evaluating the accuracy of one-piece and three-piece 3D-printed indirect bonding transfer trays: An in vitro study},
  journal = {Dental and Medical Problems},
  year = {2024},
  doi = {10.17219/dmp/184145}
}
Kostenlos starten →