EUVIMEDOpdag EUVIMED
Vergleichsstudie

Urgent off-pump coronary artery bypass grafting

Hitoshi Hirose, Atushi Amano, Akihito Takahashi, Shuichirou Takanashi

The Japanese Journal of Thoracic and Cardiovascular Surgery · 2002-08 · 50 (8) · 330-337

DOI: 10.1007/bf03032626 ↗

At a glance

Vergleichsstudie in The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002-08. Written by Hitoshi Hirose and 3 co-authors. Institution: Department of Cardiovascular Surgery, Kobari General Hospital, 29-1 Yokouchi, Noda City, Chiba 278-8501, Japan. Major MEDLINE topics: Coronary Artery Bypass, Intra-Aortic Balloon Pumping. Cited 6 times so far (Crossref); 20 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

OBJECTIVES: The use of off-pump coronary artery bypass grafting (CABG) has become widespread, since it has proven less invasive and to promote early recovery. In this study, we investigated the efficacy of off-pump CABG in patients in the evolving phase of acute myocardial infarction. METHODS: Retrospective chart review was carried out for patients undergoing urgent isolated off-pump and on-pump CABG at Shin-Tokyo Hospital Group between January 1991 and June 2001. The patients' demographic, operative data, and postoperative results were collected. RESULTS: The off-pump group consisted of 19 males and 11 females with a mean age of 72.0 years and the on-pump group of 91 males and 38 females with a mean age of 64.3 years. Preoperative use of intraaortic balloon pumping and preoperative shock was more frequently observed in the on-pump group. The mean number of distal anastomoses was 3.1 +/- 0.9 in the off-pump group and 3.2 +/- 1.1 in the on-pump group (p = NS). Intubation time (18.5 vs 32.9 hours), ICU stay (3.4 vs 4.9 days), and postoperative stay (13.5 vs 24.3 days) were significantly shorter in the off-pump group than in the on-pump group (P < 0.05). The frequency of the major complications was significantly lower in the off-pump group (9/30, 30%) than the on-pump group (65/129, 50.4%), especially for postoperative low output syndrome (p < 0.05). Multivariate analysis demonstrated a significant reduction in the recovery period by use of off-pump CABG. Early follow-up results were similar between the two groups, in terms of late cardiac events and survival. CONCLUSION: Urgent off-pump CABG is safe and provides early recovery, provided that the patient's intraoperative hemodynamics are taken into account.

Subjects

MeSH terms (MEDLINE)

Coronary Artery BypassIntra-Aortic Balloon PumpingAgedFemaleHumansMaleMiddle AgedMyocardial InfarctionRetrospective StudiesTreatment Outcome

Authors and institutions

  • Department of Cardiovascular Surgery, Kobari General Hospital, 29-1 Yokouchi, Noda City, Chiba 278-8501, Japan.

Cite

APA

Hirose, H., Amano, A., Takahashi, A., & Takanashi, S. (2002). Urgent off-pump coronary artery bypass grafting. The Japanese Journal of Thoracic and Cardiovascular Surgery, 50(8), 330-337. https://doi.org/10.1007/bf03032626

Vancouver

Hirose H, Amano A, Takahashi A, Takanashi S. Urgent off-pump coronary artery bypass grafting. The Japanese Journal of Thoracic and Cardiovascular Surgery. 2002;50(8):330-337. doi:10.1007/bf03032626

BibTeX
@article{Hirose2002,
  author = {Hirose, Hitoshi and Amano, Atushi and Takahashi, Akihito and Takanashi, Shuichirou},
  title = {Urgent off-pump coronary artery bypass grafting},
  journal = {The Japanese Journal of Thoracic and Cardiovascular Surgery},
  year = {2002},
  volume = {50},
  number = {8},
  pages = {330--337},
  doi = {10.1007/bf03032626}
}
Start for free →