EUVIMEDEUVIMED entdecken
Crossref

Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperature

P R Freund, G L Brengelmann

Journal of Clinical Monitoring · 1990-10 · 6 (4) · 266-270

DOI: 10.1007/bf02842485 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Monitoring, 1990-10. Verfasst von P R Freund und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University of Washington, Seattle. Hauptthemen laut MEDLINE: Body Temperature, Esophagus, Respiratory Sounds, Thermometers. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 11 Literaturangaben. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The esophageal stethoscope has evolved into a device for both acoustic and core temperature monitoring. To test whether routine placement according to acoustic criteria results in placement of the core temperature sensor in the region of contiguity between the esophagus and the heart, we determined the depth of placement electrocardiographically. All patients were undergoing nonthoracic elective operations requiring general anesthesia and tracheal intubation. First, we established that different observers selected the same esophageal depth within +/- 1 cm electrocardiographically, using the criterion of a symmetric biphasic P wave of maximal amplitude (7 patients). Then, in 30 more patients, we compared routine acoustic placements with the depths of the maximal-amplitude biphasic P wave. Stethoscopes placed according to acoustic criteria were within +/- 3 cm of P-wave depths in 15 of 30 patients. In the remaining patients, measured discrepancies ranged up to 13.5 cm. We conclude that the prevailing stethoscope design, with a thermistor at the tip, below the acoustic window, does not ensure placement of the thermistor within the optimal region for monitoring of core temperature. A modification in design that would take advantage of the reliability of electrocardiographic positioning is suggested.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body TemperatureEsophagusRespiratory SoundsThermometersAcousticsAdultAgedAtrial Function, LeftAuscultationElectrocardiographyEquipment DesignHeart AuscultationHumansMiddle AgedMonitoring, IntraoperativeReproducibility of ResultsSingle-Blind Method

Autor:innen und Institutionen

  • Department of Anesthesiology, University of Washington, Seattle.

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Freund, P. R., & Brengelmann, G. L. (1990). Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperature. Journal of Clinical Monitoring, 6(4), 266-270. https://doi.org/10.1007/bf02842485

Vancouver

Freund PR, Brengelmann GL. Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperature. Journal of Clinical Monitoring. 1990;6(4):266-270. doi:10.1007/bf02842485

BibTeX
@article{Freund1990,
  author = {Freund, P R and Brengelmann, G L},
  title = {Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperature},
  journal = {Journal of Clinical Monitoring},
  year = {1990},
  volume = {6},
  number = {4},
  pages = {266--270},
  doi = {10.1007/bf02842485}
}
Kostenlos starten →