EUVIMEDObjevte EUVIMED
Vergleichsstudie

Treatment planning and dosimetry of a multi-axis dynamic arc technique for prostate cancer: A comparison with IMRT

Kenshiro Shiraishi, Keiichi Nakagawa, Hideomi Yamashita, Naoki Nakamura, Masao Tago, Kuni Ohtomo

Radiation Medicine · 2006

DOI: 10.1007/bf02489984 ↗

At a glance

Vergleichsstudie in Radiation Medicine, 2006. Written by Kenshiro Shiraishi and 5 co-authors. Institution: Department of Radiology, University of Tokyo Hospital, Japan. Major MEDLINE topics: Radiotherapy, Intensity-Modulated. Cited 5 times so far (Crossref); 21 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

PURPOSE: Intensity-modulated radiation therapy (IMRT) allows greater dose conformity to the tumor target. However, IMRT, especially static delivery, usually requires more time to deliver a dose fraction than conventional external beam radiotherapy (EBRT). The authors have been using a "two-axis dynamic arc therapy" (2A-DAT) technique for prostate cancer treatment to make a concave dose distribution to spare the rectum and bladder while working with limited time and human resources. The objectives of this study were to (1) clinically implement the 2A-DAT technique, (2) evaluate the dosimetry in comparison with IMRT, and (3) analyze the initial treatment outcome. MATERIALS AND METHODS: The 2A-DAT consists of two dynamic arc therapies (DATs) with half rotation around two isocenters each in two separate symmetrical rhombi. Treatment planning is forward and on a trial-and-error basis. Thirty-four patients received 2A-DAT with a median prescribed dose of 70 Gy. RESULTS: Although inferior in dose uniformity, the 2A-DAT provided equivalent sparing of normal structures to IMRT. Daily fraction delivery time for the 34 patients ranged from 6.4 to 9.6 minutes, with an average of 7.4 minutes. Five-year survival and five-year prostate specific autigen (PSA) failure-free survival were 89.3% and 79.5%, respectively. Three patients developed grade 2 proctitis. CONCLUSION: This technique is a possible alternative to IMRT in EBRT of prostate cancer.

Subjects

MeSH terms (MEDLINE)

Radiotherapy, Intensity-ModulatedAgedDose Fractionation, RadiationHumansMaleProstatic NeoplasmsRadiotherapy DosageRadiotherapy, Computer-AssistedRadiotherapy, ConformalRectumTreatment OutcomeUrinary Bladder

Authors and institutions

  • Department of Radiology, University of Tokyo Hospital, Japan.

Cite

APA

Shiraishi, K., Nakagawa, K., Yamashita, H., Nakamura, N., Tago, M., & Ohtomo, K. (2006). Treatment planning and dosimetry of a multi-axis dynamic arc technique for prostate cancer: A comparison with IMRT. Radiation Medicine. https://doi.org/10.1007/bf02489984

Vancouver

Shiraishi K, Nakagawa K, Yamashita H, Nakamura N, Tago M, Ohtomo K. Treatment planning and dosimetry of a multi-axis dynamic arc technique for prostate cancer: A comparison with IMRT. Radiation Medicine. 2006. doi:10.1007/bf02489984

BibTeX
@article{Shiraishi2006,
  author = {Shiraishi, Kenshiro and Nakagawa, Keiichi and Yamashita, Hideomi and Nakamura, Naoki and Tago, Masao and Ohtomo, Kuni},
  title = {Treatment planning and dosimetry of a multi-axis dynamic arc technique for prostate cancer: A comparison with IMRT},
  journal = {Radiation Medicine},
  year = {2006},
  doi = {10.1007/bf02489984}
}
Start for free →