Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system

W Desmet, J L Willems, M Vrolix, J van Lierde, G Byttebier, J Piessens

The International Journal of Cardiac Imaging · 1993

DOI: 10.1007/bf01137151 ↗

At a glance

Journal article in The International Journal of Cardiac Imaging, 1993. Written by W Desmet and 5 co-authors. Institution: Department of Cardiop6gy, University Hospital Gasthuisberg, Leuven, Belgium. Major MEDLINE topics: Online Systems. Cited 11 times so far (Crossref); 17 references.

SažetakSubjectsBibliografski podaciCiteRelated studies

Abstract (original language)

To evaluate intra- and interobserver variability of an on-line quantitative coronary angiographic system, 2 independent observers measured 166 primary lesions excluding total occlusions before and after coronary angioplasty. Each observer repeated his measurement 3 times at 14 days interval. The average percent diameter stenosis results obtained by observer 1 and 2 were almost identical, before (62.2% +/- 12.0% and 62.6% +/- 11.4%, NS) and after (27.1% +/- 12.0% and 26.9% +/- 11.3%, NS) angioplasty. Variability was expressed as 95% limits of agreement (mean difference +/- 2 x SD). The intra-observer variability of observer 1 ranged from -6.6% to 6.6% before angioplasty and from -9.6% to 9.6% after angioplasty. The corresponding limits of observer 2 were -8.0% to 7.5% and -8.3% to 8.5%, respectively. The interobserver variability ranged from -10.4% to 9.6% before versus -12.5% to 13.1% after angioplasty. This variability was not influenced by vessel size. The widening of the limits observed after angioplasty was largely due to an increased variability in the measurements of the absolute minimal luminal diameter but not of the reference segment. We conclude that the intra- and interobserver variability of measurements obtained with an on-line quantitative angiographic system used for guiding coronary interventions is acceptable and without systematic bias in any direction for a wide range of primary coronary stenoses. However, the variability increases when images are acquired immediately after angioplasty.

Subjects

MeSH terms (MEDLINE)

Online SystemsAngioplasty, Balloon, CoronaryBelgiumCoronary AngiographyHumansObserver Variation

Authors and institutions

  • Department of Cardiop6gy, University Hospital Gasthuisberg, Leuven, Belgium.

Cite

APA

Desmet, W., Willems, J. L., Vrolix, M., van Lierde, J., Byttebier, G., & Piessens, J. (1993). Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system. The International Journal of Cardiac Imaging. https://doi.org/10.1007/bf01137151

Vancouver

Desmet W, Willems JL, Vrolix M, van Lierde J, Byttebier G, Piessens J. Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system. The International Journal of Cardiac Imaging. 1993. doi:10.1007/bf01137151

BibTeX
@article{Desmet1993,
  author = {Desmet, W and Willems, J L and Vrolix, M and van Lierde, J and Byttebier, G and Piessens, J},
  title = {Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system},
  journal = {The International Journal of Cardiac Imaging},
  year = {1993},
  doi = {10.1007/bf01137151}
}
Start for free →