EUVIMEDOpdag EUVIMED
Crossref

Automated evoked potential monitoring

S A Hyman, P H King, J Xu

International Journal of Clinical Monitoring and Computing · 1993

DOI: 10.1007/bf01133011 ↗

At a glance

Journal article in International Journal of Clinical Monitoring and Computing, 1993. Written by S A Hyman and 2 co-authors. Institution: Vanderbilt University, School of Medicine, Dept. of Anesthesiology, Nashville, TN 37232-2125. Major MEDLINE topics: Diagnosis, Computer-Assisted, Evoked Potentials. 106 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

We have developed a computer system for use in the operating room and intensive care unit for the automated acquisition and classification of flash evoked potentials. The project goals were to: (1) acquire evoked potentials without user intervention; (2) recognize, label, and trend important parameters; and (3) alarm if parameters deviate too far from normal. The system consists of a Nicolet Pathfinder, programmed for periodic flash visual evoked potential acquisition and a personal computer for analysis. Analysis software utilizes the C+ +language. The system has been tested on sixteen cases, determinations of specific waveforms were validated ex post facto by two experts. Three parameters in each of three channels were correctly recognized in more than 87% of all waveforms acquired. No signals at all were obtained in only 0.8% of all samples.

Subjects

MeSH terms (MEDLINE)

Diagnosis, Computer-AssistedEvoked PotentialsElectroencephalographyElectronic Data ProcessingEvoked Potentials, VisualHumansMicrocomputersMonitoring, PhysiologicNervous System DiseasesPilot ProjectsPredictive Value of TestsReaction TimeSignal Processing, Computer-AssistedSoftware

Authors and institutions

  • Vanderbilt University, School of Medicine, Dept. of Anesthesiology, Nashville, TN 37232-2125.

Cite

APA

Hyman, S. A., King, P. H., & Xu, J. (1993). Automated evoked potential monitoring. International Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/bf01133011

Vancouver

Hyman SA, King PH, Xu J. Automated evoked potential monitoring. International Journal of Clinical Monitoring and Computing. 1993. doi:10.1007/bf01133011

BibTeX
@article{Hyman1993,
  author = {Hyman, S A and King, P H and Xu, J},
  title = {Automated evoked potential monitoring},
  journal = {International Journal of Clinical Monitoring and Computing},
  year = {1993},
  doi = {10.1007/bf01133011}
}
Start for free →